LDK 5417 + LDK 4417 User’s Guide | Mains power supply
19
7 Mains power supply
7.1 Adapting the Base Station to the mains voltage
According to equipment serial number, the power supplies equipping the Base Station are:
•
Bivoltage (fitted with an automatic switching system: 100 to 125 V AC
and
200 to 240 V
AC 50 or 60 Hz). In this case, no adaptations are required in terms of mains voltage.
•
Or monovoltage 100 to 125V AC
or
200 to 240V AC 50 or 60 Hz.
Caution
Before connect the Base Station to the mains, to make sure of the equipment operation
voltage. This voltage is indicated on the label located on the Base Station rear panel.
7.2 Fuse changing
The fuse is located in the mains connector on the back of the Base Station.
•
Disconnect the mains plug for access to fuse.
•
This connector also contains a spare fuse.
Fuse type:
110V or 220V: Value T 6,3 AH 250V Fuse reference: T9000671
2 fuses:
•
Equipment protection fuse.
•
Spare fuse.