Chapter 3 Installing the Level 2R Storage System
• For K2 Media Clients, refer to K2 Media Client System Guide for instructions.
NOTE: You must install MPIO software on K2 Media Clients that access shared
storage on a redundant K2 Storage System.
Basic operations for Level 2R storage
Use the following procedures as you work on your Level 2R storage system:
•
“Level 2R system power-off procedure”
•
“Level 2R system power-on procedure”
For other procedures refer to
“Administering and maintaining the K2 Storage
Level 2R system power-off procedure
Use the following sequence to power-off the Level 2R storage system.
1. Power-off all K2 Media clients or other iSCSI clients.
2. From the K2 System Configuration application, in the tree view select the name of
the K2 Storage System, which is the top node of the storage system tree. Then click
the
Server Control Panel
button.
The Server Control Panel opens.
3. Take note of which is the primary K2 Media Server and which is the backup K2
Media Server. The order in which you put servers back into service when you
power up the K2 Storage System is dependent on their primary/backup roles at the
time when you power down the K2 Storage System.
4. For the backup K2 Media Server, click
Stop
. This takes the server out of service.
5. Shut down the backup K2 Media Server, if it does not shut down automatically.
6. For the primary K2 Media Server, click
Stop
. This takes the server out of service.
7. Shut down the primary K2 Media Server, if it does not shut down automatically.
Summary of Contents for K2 BASECAMP EXPRESS
Page 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 2 071 8461 02 JULY 2007 ...
Page 8: ...8 K2 Storage System Instruction Manual July 3 2007 Contents ...
Page 14: ...14 K2 Storage System Instruction Manual July 3 2007 Safety Summaries ...
Page 20: ...20 K2 Storage System Instruction Manual July 3 2007 Finding Information ...
Page 24: ...24 K2 Storage System Instruction Manual July 3 2007 Chapter 1 Product Description ...
Page 67: ...July 3 2007 K2 Storage System Instruction Manual 67 ...
Page 300: ...300 K2 Storage System Instruction Manual July 3 2007 Chapter 8 Overview of K2 Storage Tools ...