322
Maintenance & Troubleshooting
Replacing the UCP
-
3901’s Fan
Re-apply power to the UCP
-
3901 and restore system operation to see if the fan alarm
becomes inactive.
The UCP
-
3901’s onboard circuitry monitors the fan motor’s rotational speed to detect that
the fan is rotating fast enough to provide sufficient cooling; it raises a fan alarm when the
fan’s rotational speed has gone below a factory-set threshold.
When the UCP
-
3901’s fan is not rotating fast enough (as detected by a fan alarm), is making
abnormal noises, or is not rotating at all, the fan is worn out and it must be replaced with a
new one.
Replacing the UCP
-
3901’s Fan
Fan Replacement Kit
The replacement fan kit is available by contacting Technical Support. See
Required Tools
The following field-supplied material is required:
• Compressed air to remove dust from the UCP
-
3901.
• Needle-nose pliers to separate push pins from the PCB.
• Curved tweezers to disconnect the fan’s power connector from the UCP
-
3901’s main
board.
• Anti-static bag or anti-static work surface to reduce the possibility of electrostatic
discharge damage to the UCP
-
3901’s electronics.
Cooling Fan Replacement Procedure
The cooling fan is located on the UCP
-
3901 PCB card.
Cooling Fan Assembly
Power Connector J14
Summary of Contents for IQUCP25
Page 8: ...8 Notices ...
Page 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...
Page 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...
Page 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...
Page 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...
Page 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...
Page 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...