MV-801 User Manual
Issue 1 Revision 1
Page 17
2.2.2 Rear Panel LEDs
Multiviewer head display outputs and Ethernet ports have LED status indicators, see Figure 7.
2.2.2.1 Multiviewer Head Display Outputs
One status LED per output. Table 6 describes the LED function.
Figure 7 MV-801 Rear Panel LEDs: a) Multiviewer Head Display Outputs; b) Ethernet Ports
Ethernet Link Status LEDs (Table 7)
Multiviewer Head Display Outputs Status LEDs (Table 6)
a)
b)
Table 6
Multiviewer Head Display Output Status LED
Color
LED
Status
Blue
Licensed Output; SFP Fitted. 1080p video output signal.
Blue / White Flashing
.....
Flashes Blue/White at 1Hz.
Licensed Output; SFP fitted. 1080p with embedded audio.
Green
Licensed Output; SFP Fitted. 720p video output signal.
Green / White Flashing
.....
Flashes Green/White at 1Hz.
Licensed Output; SFP fitted. 720p with embedded audio.
Red
Licensed Output; No SFP Fitted.
Off
OFF
Unlicensed output.
Red / Green Flashing
.....
Flashes Red/Green at 1Hz
during
an internal FPGA upgrade
(part of a unit software upgrade).
Red Flashing
.....
Flashes Red/Off at 1Hz
after
a unit software upgrade if:
•
internal FPGA upgrading was unsuccessful; or
•
internal FPGAs fail to load during unit boot.
Note:
A unit upgrade to the same version may be carried out
to recover a unit if FPGA upgrading was unsuccessful.
Otherwise, contact Grass Valley support.