JUPITER — Release Notes
11
Pro-Bel SW-P-08 Protocol
Entering MPK information
You will need to make entries in the MPK Devices table for the port to asso-
ciate the Input, Output and Level sets. The Device Type is Serial with a
Serial Input and an Output set. The level type is cp3000.
Note
These steps assume that a Serial Input set, Output set, and a Level set have
already been configured. For steps to configure a CM-4000 or CM-4400 see
the
CM-4000 or CM-4400 Control Module manuals.
Follow these steps to enter or modify the MPK table:
1.
Select the MPK Devices option from the Jupiter menu (Jupiter> MPK
Devices). The MPK Devices table will then open.
2.
Enter a name in the MPK Devices column.
3.
Click the Device Type drop-down list and then select the Serial option.
4.
Click the Board drop-down list and then select the preferred board.
5.
Enter the Port number in the Port column.
6.
Select the Input Sets drop-down list and then select the preferred Serial
input set.
7.
Select the Output Sets drop-down list and then select the preferred
Serial Output set.
8.
Select the Level Sets drop-down list and then select the preferred Serial
Level set.
9.
Click the
Apply
button and then save your changes (See line #5 in
).
Figure 5. MPK Device Table
Pro-Bel SW-P-08 Protocol Commands
This section provides the command, and a description for the commands,
that are implemented to interface with a Studer Router switcher using the