10
JUPITER — Release Notes
Version 7.9.0
Note
On the Title bar of the Jupiter Configurator application you will see the name
of the Configuration set. Make sure that the configuration set that is opened
is the correct set that you want to change.
Follow these steps to enter or modify the Serial Protocol table:
1.
Select the Serial Protocol option from the Jupiter menu (Jupiter > Serial
Protocol). The Serial Protocol table will then open (
).
Figure 3. Example of the Serial Protocol Table
2.
Double−click the protocol box that is associated with the Serial port. A
drop-down list will show the possible protocol types.
3.
Select the P08 (SW-P-08 Control Panel) protocol.
4.
Click anywhere else in the table to close the entry. The default Baud
rates will be selected automatically; however, the Baud rate may be
changed by clicking the drop down menu (
).
Figure 4. The P08(SW-P-08 Control Panel) Protocol on The Serial Protocol Table
5.
Click the
Apply
button and then save your changes.
Note
The serial line parameters are:
•
38400 Baud
•
8 data bits
•
No parity
•
1 stop bit
•
The baud rate is adjustable
Protocol
Baud Rate