100
APEX — Installation and Service Manual
Section 3 — Installation
Jupiter Control
Jupiter control requires connection of a CM-4000 or VM-3000 Crosspoint
bus cable to an Apex equipped with a CX-34000 Control XPT board
(
). The VM/CM can receive switching commands from a variety
of serial sources, including Jupiter control panels or an automation com-
puter.
Note
Systems larger than 512 x 512 stereo (or larger than 1024 x 1024 mono)
cannot be controlled by a VM-3000.
Note
Stereo mode switching (mix, reverse, etc.) is not available for Jupiter-con-
trolled systems with more than 512 inputs.
Figure 44. Control Connections to Jupiter Facility Control System (Example)
CM-4000
VM-3000
System
Controller
MPK bus
Apex routing
switcher
Crosspoint bus
Jupiter control panels
Media
converter/
switch
Jupiter file
server
10/100BaseT
LAN
10Base2
LAN
T
T
T
Ungrounded
50-ohm terminator
=