Step 1: Select Control System 

Control panel modes are set using DIP switch 6. See table below: 

 
 
 
 
 

 
 

 

DIP Switch Configuration 

 

Note: DIP switches not identified below can be set either up or down. 

 

DIP switches configure the Control 
System, Communications Type, and 
GPIO Override. 

 

DIP Switches 

 

Switch 

Function 

Switch 

Position 

Up 

Down 

GPIO—Overrider Input Normal  Button mimic[1] 

Control System 

6026777 and 6027778 

panels on a Nebula 

controller 

All other panel types and 

controllers 

10 

Communications 

RS485 Ethernet 

[1] 

Not currently used 

Step 3: Connect Power 

Plug cable into 2A fused IEC 
socket 

Step 1: Select Control System 

Control panel modes are set using DIP switch 6. 

See table below 

Step 2: Select Comms Type 

Set DIP switch 10: 

 

UP = RS485 (serial) 

 

DOWN = Ethernet 

Step 4: Setup Comms 

Connect the appropriate cable to a comms port (serial or Ethernet) and configure the port address 

-

 

Standard RS232/485 pinout Serial Cable 

-

 

Standard CAT-5 10/100 BASE-T straight-through or crossover Ethernet cable 

Summary of Contents for 6026 Series

Page 1: ...6026 Series 2U Control Panels Quick Setup Guide ...

Page 2: ... Panel Equivalent 6026778 6277 20 40 Multi bus Panel Equivalent 6026777 6277 60 80 Multi bus Panel Equivalent LCD Control Panel 6026783 The LCD panel has a 64x32 pixel LCD on each key and a single rotary encoder The LCD panel is compatible with Aurora control systems ...

Page 3: ... mimic 1 6 Control System 6026777 and 6027778 panels on a Nebula controller All other panel types and controllers 10 Communications RS485 Ethernet 1 Not currently used Step 3 Connect Power Plug cable into 2A fused IEC socket Step 1 Select Control System Control panel modes are set using DIP switch 6 See table below Step 2 Select Comms Type Set DIP switch 10 UP RS485 serial DOWN Ethernet Step 4 Set...

Page 4: ...rop address must match database configuration Set DIP switches 1 and 2 down to terminate long cable runs or the end of a multi drop chain Hex Switch 1 sets the multi drop address Switch 1 2 3 4 5 6 7 8 9 A B C D E F 0 Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ...

Page 5: ...browser type the default IP address 192 168 1 1 and press Return 3 IntheControlPanelSetupscreenthatdisplaysinthebrowser typethenewcontrol panel IP address subnet mask and gateway 4 TypetheNucleuscontrollerIPaddressesandportnumbers Controllerportnumbers must be greater than 1024 excluding3000 5 Click Submit Settings 6 Click Reset Control Panel Key Brightness Hex switch 2 sets the brightness of the ...

Page 6: ...530 478 4148 To obtain a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from the website Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...