Grant's Automation
AN1808-12M
4G
Audio Intercom (E2.2)
10/16
Enter System Menu
1.
Please call the number of the
4G
intercom device.
2.
The device will answer and sound one beep to enter system menu.
3.
Enter the password of the mode you would like to enter.
3.1
Listener monitoring mode:
【
*13*1212
#】
3.2
Access control mode:
【
*33*5678
#】
3.3
Program setting mode:
【
*12* 1234
#】
4. Password correct is one beep, password error is 3 beeps.
5. The intercom will hang up after 3 failed attempts.
Enter Listener Monitoring Mode
1. You will hear a “Do” tone to enter listener monitoring mode by pressing
【
*13*1212
#】
where 1212 is the monitoring password.
2. Then you can hear the live sound of the device’s surrounding environment.
* Under this mode speaker is OFF. (35
#
: To turn on
speaker)
* You can still control the relay output under listener monitoring mode but speaker must be
ON status.
Enter Access Control Mode
1. You will hear a “Do” tone to enter access control mode by pressing
【
*33*5678
#】
where
5678 is the access control password.
2. The door will be opened after entering the correct password
* (To open the door by password, if the number is not stored in the call in numbers)
Enter Program setting Mode
1. You will hear a “Do” tone to enter into program setting mode by pressing
【
*12* 1234
#】
where 1234 is the setting password.
2. You are now in the “program setting mode”
Note: At the end of each command there can be one of the two indications:
Successful: a long “beep” tone, failed: three short “beep” tone.
3. To make changes on settings please refer to the command codes in page 12.
4. To end program setting mode just hang up.
NOTE:
*To be successful in programming, originate a call from a land line and enter the
digits slowly or using programming by text message.