background image

Grant's Automation 

 

AN1808-08 

 

4G

 Audio Intercom (E2.2) 

  4/16 

Introduction 

AN1808-08 

 

4G

 audio intercom system is designed for units or multi tenanted premises. It can dial 

up to 8 different destinations.  By pressing the relevant call button, a visitor can be connected to 

the occupier whether they are on or off the site. The intercom will sequentially call 3 numbers that 

are associated with the occupier. After the call is answered the door or gate can be opened by 

password. 

Up to 1150 guests’ numbers can be programmed into this intercom. Any guest calling the intercom 

will cause the gate or door to open without the call being answered. This is a free call. 

This intercom supports all Telstra, Optus & Vodafone CSFB networks. 

Parts List 

Item 

Description 

Q’ty 

AN1808-08 

 4G audio intercom 

Power adapter 

Antenna with 3 metre tail 

Mounting Bracket for antenna 

Operating manual 

6 Pin Cable 

Terminal Blocks 

Mounting Bracket 

Summary of Contents for AN1808-08

Page 1: ...Grants Automation AN1603 08 4G Audio Intercom E2 2 1 16 AN1808 08 4G LTE INTERCOM ACCESS CONTROL OPERATING MANUAL For your protection read these instructions completely Keep for future reference ...

Page 2: ... Installation 5 Wiring Diagram 8 Using the AN1808 08 9 1 Setting your call out numbers 9 2 Setting your call in numbers Guest List 9 5 App on iOS and Android 9 Programming by text message 10 Command Codes 12 How to reset the hardware if you forget your password 15 How to change the name plate 14 Troubleshooting Q A 15 Specification 16 ...

Page 3: ...duct 2 Unplug all the connections of product before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning 3 Do not use this product near water 4 Do not use this product near an area where there is a potential of gas leaks or near any fumes that can be explosive 5 Do not place this equipment near or over a radiator or any other heat source 6 Do not overload the wall ...

Page 4: ...re associated with the occupier After the call is answered the door or gate can be opened by password Up to 1150 guests numbers can be programmed into this intercom Any guest calling the intercom will cause the gate or door to open without the call being answered This is a free call This intercom supports all Telstra Optus Vodafone CSFB networks Parts List Item Description Q ty 1 AN1808 08 4G audi...

Page 5: ...Grant s Automation AN1808 08 4G Audio Intercom E2 2 5 16 Installation This intercom is suitable for both flush mounting and surface mounting ...

Page 6: ...r from the bottom of the unit 1 4 Slide the SIM card holder towards the front of the unit 1 5 Lift up the holder 1 6 Before inserting the SIM card ensure that it is not PIN number locked If locked use a mobile phone to unlock it 1 7 Insert the SIM card Note orientation of notched corner 1 8 Replace holder and slide towards the rear of the unit to lock in place 1 9 Replace rear plastic cover ...

Page 7: ... the door lock system Fig 2 2 1 According your door lock type see wiring options below 3 Connecting the Antenna Fig 3 3 1 Plug in the antenna cord to the connector on the rear of the unit 3 2 Place antenna away from electrical electronic systems computers microwave ovens etc ...

Page 8: ...n 4 1 Connect the 12 24v power source to the connector marked AC 4 2 The blue indicator of call button should be on and you will hear Du Du tone 4 3 Position the intercom where it will be installed 4 4 When the Du Du tone has ceased the device is ready Wiring Diagram ...

Page 9: ...ist 2 1 Send the text SMS to the number of device 2 2 The format of text SMS is 12 1234 71 country code 72 relay call in number 1 72 relay call in number 2 2 3 When the setting is finished the sender will receive the reply as below 71 country code 72 relay call in number 1 72 relay call in number 2 OK 2 4 If a guest calls the number of the device it will trigger the relay to control the door latch...

Page 10: ... control the relay output under listener monitoring mode but speaker must be ON status Enter Access Control Mode 1 You will hear a Do tone to enter access control mode by pressing 33 5678 where 5678 is the access control password 2 The door will be opened after entering the correct password To open the door by password if the number is not stored in the access control section Enter Program setting...

Page 11: ...ately by a command 4 To program a call button numbers DO NOT enter country code just the complete number as you would dial it Example Store a call button phone numbers Max 3 numbers and delete 2 3 phone numbers 058 57235 landline number 1 086 5682554 mobile number 2 086 2235644 mobile number 3 SMS format store a call button phone numbers 12 1234 108105857235 10820865682554 10830862235644 SMS forma...

Page 12: ...icrophone Volume 4 microphone volume microphone volume level 0 4 3 7 Relay 1 Trigger Time 51 relay1 time Relay 1 time 1 9999 sec 1 8 Relay 2 Trigger Time 50 relay 2 time Relay 2 time 1 9999 sec 1 9 Call Divert to next number time 52 call divert time Call divert time 10 99 sec 20 sec 10 Max Call Time 53 max call time Max call time 005 999 sec 060 sec 11 Max Monitoring time 55 duration time duration...

Page 13: ... enable 0 25 Change the length of open code 940 X X 1 1 code open code X 2 2 codes open code 1 26 Change open codes of relay 1 2 including trigger hold release for independent apartment 93 X ABCDEF X apartment number A B C D E F 0 9 and A trigger relay 1 B hold relay 1 C release relay 1 D trigger relay 2 E hold relay 2 F release relay 2 1 code 2 code 1 2 3 4 5 6 10 20 30 40 50 60 27 Send SMS messa...

Page 14: ...io Intercom E2 2 14 16 works for inside battery 31 Send SMS message when IN1 is triggered 30 password content Password setting password content up to 100 characters IN1 trigger 32 Reset 999 reset default None How to change the name plate ...

Page 15: ...he unit calls the first number but there is not enough time to answer before it diverts to the next number A Increase the no answer time as per programming instructions Q The unit calls the first number but voicemail comes on before it can ring the second number A Decrease the no answer time as per programming instructions Q The caller ID part does not work A Be sure to program the caller ID part ...

Page 16: ...be heard then the system is working check wiring between the relay and the lock or gate panel If the relays do not make a clicking sound then check this feature on a different mobile cell phone or landline If it works on a different phone check the settings on the phone in question under DTMF tones Failure of DTMF tones to operate correctly is also a symptom of low reception Check steps above on i...