background image

SQ2010  

28507 Version 6 

Page 6 

EN 

    The Logger 
Setup screen 
is now visible, 
from here you 
will be able to 
set up your 
logging 
requirements. 

Within the 
Actual 
Channels tab 
scroll down the 
Sensor Type 
column to Ref. 
Junction 1. 
This is the 
input you will 
be reading in 
this example. 

    The Job 
Description 
can be used to 
describe your 
setup. 

    In the SquirrelView 
Assistant click „Logger 
Setup‟ to enter the Logger Setup 
screen. From here open the 
demo setfile using  

File -> Open

 

and select the appropriate file for 
your logger type. 

4.3 

Running Quick Start Demo 

 

 

 

Summary of Contents for Squirrel SQ2010 SERIES

Page 1: ...Getting Started 2010 SERIES Squirrel Data Logger www omniinstruments co uk...

Page 2: ...Start Example 5 5 Download Process Explained 9 6 Menu and Navigation 10 7 Connections 14 8 Accessories 16 9 Specifications 18 10 Declaration of Conformity Inside rear cover After reading this guide p...

Page 3: ...2010 Logger C CD containing software SQA100 D Getting Started manual this booklet E USB Cable LC77 F Batteries 2 x C G Current shunt resistors for 4 to 20mA inputs 10R x 4 CS202 H Connectors 6 way x 2...

Page 4: ...dition Battery indicator When logging please ensure that the batteries in the unit have sufficient capacity to complete the logging task This can be checked via the battery indicator located in the to...

Page 5: ...ruments SQ20XX USB device drivers Win 7 Vista USB Device Drivers are automatically installed and no further action is required Important Please ensure the software is installed before connecting the S...

Page 6: ...lView or select it from your start menu When the SquirrelView Assistant is loaded ensure the correct logger type and communication method is selected Logger type can be viewed from the SquirrelView as...

Page 7: ...ll down the Sensor Type column to Ref Junction 1 This is the input you will be reading in this example The Job Description can be used to describe your setup In the SquirrelView Assistant click Logger...

Page 8: ...stant Click if you wish to meter the input in Real Time Click on Logger Control icon to pause or stop the logging process In the Logger Control window you can view relevant information on the state of...

Page 9: ...name is shown on the right this shows the date and start time In this example you will download and view the Data in the Analysis window Start by selecting the Data File and Graph Data action then cli...

Page 10: ...process can be performed in one of three ways within SquirrelView from SquirrelView assistant Analysis Export Data File automatically when using the download Data button from SquirrelView or from the...

Page 11: ...e detail To use the 2010 control panel press the opening display will be shown see right The display timeout is preset to 10 seconds however this can be changed by selecting the Configuration tab with...

Page 12: ...larm outputs from here 6 2 4 Setup This contains menus for setting the Language Time Date basic Channel Setup storing and recalling setups and Delayed start See 6 3 for more details on basic setup 6 2...

Page 13: ...etup you can clear all channels add edit a channel view channel details or delete a channel Select Add Edit Channel 6 3 3 Adding a New Channel The Add Edit Channel menu shows channels currently set as...

Page 14: ...in the case of a more complex setup from SquirrelView To avoid problems with wiring configuration sensor types are not editable once set but their range and sensor power requirements can be Delete a...

Page 15: ...wiring diagram to attach the required sensor If you would like to print the diagrams in more detail or view at a later stage select File Print from Logger Setup Analogue Inputs The example below show...

Page 16: ...2 Event State Input 2 3 Event State Input 3 4 Event State Input 4 5 Event State Input 5 6 Event State Input 6 7 Event State Input 7 8 Event State Input 8 9 Ground 10 Alarm Output A 11 Alarm Output B...

Page 17: ...our local supplier for more details RS232 to Ethernet Converter consisting of adaptor box and modem setup Part No Cable Ethernet configuration software is suitable for Windows XP only SQ20A801 GSM Mod...

Page 18: ...lead MPU 12VFL Rechargeable battery 12V 6Ah SQ20RB12 6 Rechargeable battery 12V 15Ah SQ20RB12 15 Digital I O interface connector 25 way D connector type sub miniature solder connection with cover for...

Page 19: ...24bit Sampling rate Up to 10 readings per second ALARM OUTPUTS 2 x open drain FET 18V 0 1A Max SENSOR POWER SUPPLY Regulated 5 VDC 50mA or supply voltage 100mA TIME AND DATE In built clock in 3 format...

Page 20: ...overwrite DISPLAY AND KEYPAD 128 x 64 pixel LCD OPERATING ENVIRONMENT 30 C to 65 C Using Supplied Batteries 20 C to 50 C Windows is a registered trademark of Microsoft Corporation in the United States...

Page 21: ...SQ2010 28507 Version 6 Page 20 EN Personal Notes...

Page 22: ...d Standards EN 61326 1 2006 Electrical Equipment for measurement control and laboratory use EMC requirements Part 1 General requirements Emissions tested for Class B equipment Immunity tested to Table...

Page 23: ...or Pricing and any further information please contact Omni Instruments Ltd Suite E Ground Floor East Kingsway Business Centre Mid Craigie Trading Estate Mid Craigie Road Dundee DD4 7RH Email info omni...

Reviews: