User Instructions

Page 4

 Introduction

These instructions are intended to assist the user with the operation of a Grant 
Aerona³ air source heat pump. Full details on the Installation, Commissioning 
and Servicing of the heat pump are contained in the Installation Instructions 
supplied with the unit.

 About your Heat Pump

Your Grant Aerona³ air source heat pump is a highly effi cient and fully 
automatic unit that extracts heat energy from the outside air to heat your 
home.

The Grant Aerona³ is an ‘air to water’ heat pump. In operation, the fan (or 
fans) draws air through the fi nned coil evaporating the refrigerant in the heat 
pump. This refrigerant is then compressed to increase its heat energy before it 
passes through a heat exchanger transferring that heat energy to the water of 
your heating system.

 Heat Pump display Pad 

Your heat pump will usually be fi tted with a display pad(refer to Figure 1). This 
will be electrically connected to the heat pump outside, but will be located in 
a convenient position within your home.

Figure 1: 

Heat pump display pad   (with door closed)

The display pad has three principle functions. 

• 

The fi rst is to enable the heat pump operating parameters to be accessed 
and adjusted as required by the heat pump installer.

• 

The second is to provide a simple means of switching the heat pump ON 
or OFF as and when required using the ON/OFF button (1). Refer to the 
‘Switching the Heat Pump ON or OFF’ section in these User Instructions.

•  Thirdly, in the event that a fault is detected, a red LED on the ON/OFF 

switch of the display pad will fl ash and a warning icon and error code 
will be displayed on LCD screen and also on the Terminal PCB display.

The heat pump is supplied with the operating parameters set to the factory 
default values. However, these parameter settings should have been checked 
by the installer when the heat pump was commissioned and adjusted where 
necessary to ensure they are correctly set to suit your particular installation. 

These heat pump operating parameters should NOT then be altered other 
than by either the installer or a Grant Service Engineer if and when necessary. 

When switched ON, the display pad screen will display both the outside air 
temperature and inside air temperature (for the area where the display pad is 
located). 

The installer should have set the correct day and time that is also displayed on 
the display padscreen. If not, refer to the instructions provided in Section 9.2 
of the Installation Instructions supplied with the heat pump. 

Heating System Controls

Your Grant Aerona³ heat pump is NOT controlled by the display pad but will 
usually be controlled by a normal domestic heating control system. 

This control system will typically consist of the following controls: 

Room thermostats, programmable or non progammable, which keeps the 
areas at the desired temperatures. 

A room thermostat

This allows the required air temperature to be set. When the air temperature 
is below this setting the thermostat will ‘call’ for the heat pump to operate to 
provide heating. This is usually located in a downstairs area such as a hallway 
or living room, but you may have more than one room thermostat if your 
heating system is ‘zoned’.

Cylinder thermostat

This controls the temperature of the water in your hot water cylinder, provided 
that your hot water cylinder is being heated by the heat pump. When the 
water temperature in the cylinder is below the thermostat setting it will ‘call’ 
for the heat pump to operate to heat the hot water. Heating the hot water is 
given priority on all heat pump systems and the recommended setting prior to 
commissioning is 47°C.
The above is only a general description of the heating and hot water system 
controls that you may have. You must refer to the manufacturers’ operating 
instructions provided with these controls for full details of their correct setting 
and operation. 

The operation and setting of these system controls should be explained to you 
by the installer.

NOTE

NOTE

The heat pump display pad does NOT control 
the ON and OFF times or temperatures of 
your heating system. These are controlled 
by your heating system controls. Refer to the 
‘Heating System Controls’ section of these User 
Instructions. 

In normal running mode your heating 
system remains on all the time. To adjust 
the temperature in house use the room 
thermostats. For  domestic hot water this is set 
as hot water priority. 

NOTE

With the Grant Aerona³ heat pump, Grant 
recommends that the hot water heating 
periods should be set to occur when the heat 
pump is NOT operating to provide heating, i.e. 
when the programmer is set to OFF for heating.

NOTE

For the heat pump to operate to provide 
heating, the room thermostat must be ‘calling’.

Summary of Contents for Aerona 3 T205 - C

Page 1: ...IRL DOC 0016 Rev 01 00 OCTOBER 2021 Grant Aerona Air to Water High Efficiency Heat Pump Range User Instructions Heating Controls ...

Page 2: ...amage or delay however caused resulting from the use of this manual can be accepted by Grant Engineering Ireland ULC the author or others involved in its publication All good sold are subject to our official Conditions of Sale a copy of which may be obtained on application Grant Engineering Ireland ULC No part of this manual may be reproduced by any means without prior written consent WARNING CAUT...

Page 3: ...linder Digital Stat 5 Grant Hot Water Boost Kit 5 9 To Switch the Heat Pump On or Off 10 via the Display Pad To Switch the Heat Pump On or Off 10 without the Display Pad Display Pad Panel 10 Weather Compensation 11 Frost Protection 11 Looking after your Heat Pump 11 Troubleshooting 11 Contents Page 3 ...

Page 4: ...where the display pad is located The installer should have set the correct day and time that is also displayed on the display padscreen If not refer to the instructions provided in Section 9 2 of the Installation Instructions supplied with the heat pump Heating System Controls Your Grant Aerona heat pump is NOT controlled by the display pad but will usually be controlled by a normal domestic heati...

Page 5: ...rther information If fitted the Boost Kit timer should have been set by the installer to suit your installation when your heat pump was commissioned Refer to Section 5 4 of the Installation Instructions supplied with your Aerona heat pump for further details if required NOTE When setting the stat please set no higher than 47 C for most efficient running of domestic hot water NOTE The Immersion hea...

Page 6: ...rminal provided Fixing screw caps must be installed to maintain class 2 status Operating Instructions Reset The Device 1 To fully reset this unit press the recessed Reset button with a insulated blunt probe 2 A full display will show when the battery is charged then revert to the default screen No display indicates that the battery requires charging for a minimum 3 hour period Dia 2 Full display N...

Page 7: ...time Dia 8 5 Use the or to set the OFF time in the same way as for PROG 1 ON time 6 Press PROG to scroll through program 2 ON program 2 OFF program 3 ON program 3 OFF program 4 ON program 4 OFF add ing in times as required If you wish to omit programmes just leave dashes in that ON OFF location Press PROG to move to the next linked day SAT follows the 5 day group automatically Dia 9 7 Set ON OFF t...

Page 8: ...or a new day grouping for a new programme 3 For modification press PROG repeatedly to arrive at the pro gramme time requiring modification then use or button to make the change Press PROG repeatedly again to arrive at the next time requiring modification and use or button to make the change Operating mode 1 Use button to set the output mode ON Output to permanently ON and omit the program Dia 15 O...

Page 9: ...UR SWITCH 7 DAY Ideal for control of towel rails panel heaters immersion heaters fan heaters Energy saving Easy to program Boost and Advance controls Surface flush mounting Front cable entry Will fit 25 47mm back boxes SPECIFICATIONS TECHNICAL DATA SHEET TECHNICAL DATA SHEET fused timer spur switch 7 day Spur Timer 12 5mm thick pattress front plate thickness 12 5mm Dia 21 Dia 20 T205 C Product Fin...

Page 10: ...se User Instructions Display Pad Panel The operation of the heat pump is indicated in the top right hand corner of the display padscreen using the following symbols This indicates the frost protection is activate Refer to the Frost Protection section of these User Instructions This indicates the defrost cycle is active This indicates a heating demand If this is displayed on the display pad screen ...

Page 11: ...the fan outlet is not obstructed at all times To ensure that it continues to operate efficiently your Grant Aerona heat pump should be serviced annually as detailed in Section 10 of the Installation Instructions supplied with the unit Contact your installer or service engineer to carry out this work Troubleshooting If your heat pump fails to operate First check Is the power supply is switched ON a...

Page 12: ...GRANT ENGINEERING IRELAND ULC Crinkle Birr Co Offaly R42 D788 Ireland Tel 353 0 57 91 20089 Fax 353 0 57 91 21060 Email info grantengineering ie www grant eu ...

Reviews: