background image

Operating instructions for PTO pump 
 

Page 

5

 of 

12

 

 

3.2.

 

Technical specifications 

 

Unit of measure 

G280 

Max. feed rate  

Litres 

280 

Max. suction height 

Meters 

Max. supply pressure 

Bar 

30 

Max. power 

KW 

7.5 

Max. speed 

RPM 

700 

Suction connection 

Inches 

1 1/2 

Suction hose diameter 

Millimetres 

Min. 40 

Suction hose wall thickness 

Millimetres 

Min. 2.5 

Min. suction hose pressure needed 

Bar 

Pressure connection 

Inches 

1 1/2 

Pressure hose diameter 

Millimetres 

Min. 25 

Pressure hose wall thickness 

Millimetres 

Min. 4.5 

Min. pressure hose pressure needed 

Bar 

30 

PTO shaft connection 

Inches 

1 3/8 

Weight 

kilograms 

20 

Max. operating temperature of the fluid 

Degrees Celsius 

30 

 

3.3.

 

Component description 

The PTO pump described in this manual can be operated in self-priming mode. 

 
 
 

Figure 2 

 
 
 

 

Suction or 

pressure line 

Suction or 

pressure line 

Direction of 

rotation 

Summary of Contents for G280

Page 1: ...pump Page 1 of 12 Original operating instructions for PTO pump G280 Photo of PTO pump These operating instructions must be read thoroughly before use and followed These operating instructions must be...

Page 2: ...S 3 2 2 PRECAUTIONARY MEASURES 4 3 PERFORMANCE SPECIFICATIONS 4 3 1 INTENDED USE 4 3 2 TECHNICAL SPECIFICATIONS 5 3 3 COMPONENT DESCRIPTION 5 3 4 ASSEMBLY INSTRUCTIONS AND COMMISSIONING 6 4 OPERATING...

Page 3: ...alled The protective devices and their protective functions should be inspected by a competent person before using the machine Defective equipment must be repaired promptly in order to minimize the ex...

Page 4: ...supervision of an instructor 3 Performance specifications 3 1 Intended use The PTO pump is a positive displacement pump with roller rotor It is mounted directly on the flange of the PTO shaft of a veh...

Page 5: ...illimetres Min 2 5 Min suction hose pressure needed Bar 2 Pressure connection Inches 1 1 2 Pressure hose diameter Millimetres Min 25 Pressure hose wall thickness Millimetres Min 4 5 Min pressure hose...

Page 6: ...lowering are not possible and secure it in this position DANGER In the area around the PTO shaft drive and the three point linkage there is heightened risk of injury from pinch and shear points and f...

Page 7: ...is being started or the machine is running Doing so can result in severe injury or death Before first use submerge the suction hose end with the filter attachment in the fluid to be pumped Make sure t...

Page 8: ...stem is not under load If a paint touch up is necessary make sure not to obscure the instruction and product notices If necessary replace them with original spare parts Fasteners must be regularly che...

Page 9: ...with delivery 7 Disposal The separate environmentally friendly disposal of materials encourages recycling of materials Therefore after expiry of the normal service life the equipment itself and all re...

Page 10: ...Shorten suction hose Suction hose is pinched Restore flow through the suction hose or replace it A return valve is in use on the suction hose hose is empty Fill the suction hose with water Pump is wor...

Page 11: ...its sole responsibility that the PTO pump Type series identification G280 is in conformity with the provisions of Machinery Directive 2006 42 EC The product was developed in accordance with the follow...

Page 12: ...les Fax 49 4281 712 324 Postal and shipping address Wilhelm Fricke SE Zum Kreuzkamp 7 D 27404 Heeslingen Germany 13 Legal Notice Original operating instructions for PTO pump G280 Distributor Wilhelm F...