33
Service Manual TD60.C
14
Filter interval
0
Sets the display interval for “Clean Lint Filter”.
0 = no display, 1 = display every programme etc.
1
2
3
4
5
6
7
8
9
10
Condenser inter-
val
0
Sets the display interval for “Clean condenser”.
0 = no display, 1 = display every 100 programmes etc.
1
2
3
4
5
6
7
8
9
10
Total Reset
Resets all settings to factory defaults.
Service Manual TD60.C
15
Fault indicators
Error message
Cause
Action
Over Flow
• A micro switch is opened when a full conden-
sed water tank is detected. Detection begins 30
seconds after the programme starts. If the micro
switch
is open >30 seconds the programme cycle is
stopped.
• Check that the customer has emptied the tank and
restarted the machine.
• Clean hoses and check voltage and resistance of
drainage pump.
• Check that the float has not got “stuck” and check the
function of the micro switch.
Max program
time
• The programme cycle time exceeds 200 minutes.
The cycle is stopped and the programme is reset.
• High ambient temperature combined with low
heater output and low drying temperature causes
condensation to form.
• Poor condensing due to blocked external air.
• Tried spinning at a higher speed.
• Had the machine switched off for 30 minutes
before restarting.
• Good ventilation in the room.
• Ensure that the external air has free passage.
Clean filter
• Indicated when the air flow and temperature do
not match.
• Clean the filter.
Clean condenser
• Displayed automatically every 100 cycles.
• Displayed if the machine has indicated “Clean
filter” twice in a row.
• Clean condenser and filter.
• Clean other air passages.
Thermistor fault
• Thermistor circuit open.
• Thermistor malfunction.
• Check the thermistor.
Insert filter
• The filter is not correctly inserted in the lint filter
holder, which means the magnet in the lint filter
cannot trigger the sensor in the lint filter holder.
• Properly insert the lint filter in the lint filter holder.
www.groupdynamics-laundry.com
Summary of Contents for GD6
Page 2: ...2 GD6 Con ventilatore GD6 Vented version www groupdynamics laundry com sales groupdynamics lv...
Page 4: ...4 Pannellatura esterna Outer casing www groupdynamics laundry com sales groupdynamics lv...
Page 10: ...10 Schema elettrico Circuit diagram www groupdynamics laundry com sales groupdynamics lv...
Page 13: ...13 Pannellatura esterna Outer casing www groupdynamics laundry com sales groupdynamics lv...
Page 16: ...16 Parte inferiore Lower session www groupdynamics laundry com sales groupdynamics lv...
Page 20: ...20 Schema elettrico Circuit diagram www groupdynamics laundry com sales groupdynamics lv...