4
2.0 PRODUCT INFORMATION
CLEARANCE (minimum) TO COMBUSTIBLES
Top of Supply Plenum
1”
(25 mm)
Front (Maintenance)
24”
(610 mm)
Rear (Maintenance)
24”
(610 mm)
Side – Non-Access
1”
(25 mm)
Side – Access maintenance
24”
(610 mm)
Vent Pipe
0”
(0 mm)
Floor (Can be installed directly on combustible or non-combustible)
AIR/BLOWER DATA
Maximum external static pressure
0.5” wc
Maximum cooling unit capacity
3.0 tons.
Maximum air temperature rise
See pages 16 and 31
High Limit temperature
215°F
Thermostat anticipator
See thermostat instructions
MOTOR/BLOWER
KLC-100: 1/2 hp ECM / GT12-10
FAN/HIGH LIMIT CONTROL
Honeywell ST9103A1028 Fan Center & Thermo-Disk (7” stem)
THERMOSTAT
Any wall thermostat
FUEL
Not heavier than No. 2 furnace oil.
ELECTRICAL – 120 Volts, 60 Hz
Canada
Less than 12 amps, circuit protection 15 amps.
USA
13.3 amps, circuit protection 20 amps.
VENT PIPE CONNECTION
3’’ IPEX 636
CONDENSATE DRAIN
PLASTIC HOSE ½’’ diameter
CLEANOUTS
Rear Cover & Burner Opening