EN Thank you for choosing to install a product from Granberg!
In order for the product to work safely and securely, it is extremely essential that the installation instructions be followed.
The installer should read and understand all the installation instructions before installation begins.
It is the installer who is responsible for floor and wall structures meeting the set requirements and that fasteners
can withstand the forces that may occur.
The installer is also responsible for the right authority and skills being available for electric and water works.
After completed installation, the product shall be functionally tested according to sections on p. 34.
FR Merci d'avoir choisi d'installer un produit de Granberg!
Pour que le produit fonctionne en toute sécurité, il est extrêmement essentiel de suivre instructions d'installation.
L'installateur doit lire et comprendre toutes les instructions d'installation avant de commencer l'installation.
Il revient à l'installateur de faire en sorte que les structures de plancher et de mur répondent aux exigences fixées et que les
fixations puissent résister aux forces qui peuvent se produire.
L'installateur est également responsable de la bonne autorité et des compétences disponibles pour les travaux d'électricité et d'eau.
Une fois l'installation terminée, le produit doit être testé fonctionnellement selon les sections à la p. 34.
Technical data / Données techniques
Baselift 6311
120/50Hz/5.0A
1.2” / s
11.8” (300 mm)
27.6”-39.4” (700-1000 mm)
220 lb (100 kg)
1 / 10m
kg
27.6” - 39.4”
1.6” / 4.1”
0.3”
8.7”
41.1”
41.1”
R
L
23.4” - 24.6”
22.3”
18.9”
1.25” 0.6”
18.9”
45-90 hög
07366 - golv ben2
WEIGHT:
A3
SHEET 1 OF 1
SCALE:1:20
DWG NO.
TITLE:
REVISION
DO NOT SCALE DRAWING
MATERIAL:
DEBUR AND BREAK SHARP EDGES
FINISH:
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERS TOLERANCES: LINEAR:
SS-ISO 2768-m
ANGULAR:
SS-ISO 2768-m
DRAWN
CHECKED
Granberg Interior AB
Tel. +46(0)11197750
www.granberg.se
Summary of Contents for Baselift Corner 6311H
Page 7: ...7 CL960 1 L R LEFT L RIGHT R R L 930 930 36 6 930mm 36 6 930mm...
Page 8: ...8 CL960 2...
Page 9: ...9 CL960 3 16 mm M8 6x M8x16mm 13...
Page 10: ...10 CL960 4x M6 x 60mm 10 4 4x M6 Anti pinch strip Bande anti pincement BR M6x16 HEX 5 32...
Page 11: ...11 CL960 5 13 180...
Page 12: ...12 CL960 6 L...
Page 13: ...13 CL960 7 R...
Page 14: ...14 CL960 8 22 04 23 2 560 590mm 13 22 04 23 2 560 590mm...
Page 15: ...15 CL960 9 13 2x M8 2x M8X45 10 mm...
Page 16: ...16 CL960 10...
Page 17: ...17 CL960 11...
Page 20: ...20 CL960 Glue Colle 14 min 0 2 5 mm min 0 2 5 mm...
Page 21: ...21 CL960 15...
Page 22: ...22 CL960 Glue Colle 16...
Page 23: ...23 CL960 17 8x 8x M6x12 HEX 1 8...
Page 26: ...26 CL960 T10 16 mm 8x 3 x 12 mm 20 8 mm 0 315...
Page 29: ...29 CL960 T10 16 mm 8x 3 x 12 mm 23...
Page 30: ...30 Leveler Niveleur Adjustment Ajustement...
Page 31: ...31 Adjustment Ajustement 9 16...
Page 34: ...34...
Page 35: ...35...