background image

 

765041996 

Rev. 001 

11 

C4  

240 

min  

10 

10 

10 

10 

10 

duration of compressor switch off time during a room temperature probe error or inlet air probe error (code "

Pr1

"

); see also 

C5  

C5  

240 

min  

10 

30 

10 

30 

10 

duration of compressor switch on time during a room temperature probe error or inlet air probe error (code “

Pr1

"

); see also 

C4  

C6  

199 

°C/°F (1)  

80 

60 

60 

60 

60 

condenser temperature is higher than that at which the condenser overheating alarm is activated (code “

COH

"

) (7)  

C7  

199 

°C/°F (1)  

90 

65 

65 

65 

65 

condenser temperature above which the compressor shut down alarm is activated (code “

CSd

"

)  

C8  

15 

min  

compressor shut down alarm delay (code “

CSd

"

) (8)  

C10  

999 

10 h  

160 

160 

number of compressor operation hours above which the request for maintenance is triggered  
0 = the request shall never be triggered  

PARAM.   MIN. 

MAX.  

U.M.  

 DEF.  

GRAM FG 

HAV 

GRAM KG 

HAV 

GRAM FG 

FAV 

GRAM KG 

FAV 

DEFROST 

d0  

99 

h  

if d8 = 0, 1 or 2, defrost interval  
0 = interval defrost will never be activated  
if d8 = 3, maximum defrost interval  

d1  

 ‐ ‐ ‐ 

type of defrost  
0 = ELECTRIC ‐ during defrost the compressor will remain off and the defrost output will be activated; evaporator fan activity        
will depend on F2 parameter  
1 = BY HOT GAS ‐ during defrost the compressor will be switched on and the defrost output will be activated; evaporator fan        
activity will depend on F2 parameter  
2 = VIA STOPPING OF COMPRESSOR ‐ during defrost the compressor will remain switched off and the defrost output will          
remain deactivated; evaporator fan activity will depend on F2 parameter  

d2  

‐99 

99 

°C/°F (1)  

12 

12 

evaporator temperature at end of defrost; see also d3  

d3  

99 

min  

30 

30 

30 

30 

30 

if P3 = 0 or 2, defrost duration  
if P3 = 1, maximum defrost duration; see also d2  
0 = defrost will not be activated  

d4  

‐ ‐  

defrost when device is switched on (5) 1 = YES  

d5  

99 

min  

if d4 = 0, minimum time between switching on of device and activation of defrost (5)  
if d4 = 1, delay in activation of defrost after device is switched on (5)  

d6  

‐‐ 

magnitude displayed during defrost (only if P5 = 0)  
0 = room temperature or CPT temperature  
1 = if on activation of defrost, the room temperature or CPT temperature is below the “work se 

t”, at maximum “ 

work         se 

t”; if on activation of defrost, the room temperature or CPT temperature is above “work se 

t”, 

at     
     maximum the room temperature or CPT temperature on activation of defrost (9) (10) 
 2 = label “

dEF

"

 

 

d7  

15 

min  

dripping duration (during dripping the compressor will remain switched off and the defrost output will remain deactivated; if 

d16 = 0, evaporator fan activity will depend on F2 parameter); if d16 

 

0, the evaporator fan shall remain off)  

d8  

‐ ‐  

defrost activation methods  
0 = AT INTERVALS ‐ FOR TIME ‐ defrost will be activated once the device has altogether been running for time d0  
1 = AT INTERVALS ‐ FOR COMPRESSOR SWITCH‐ON ‐ defrost will be activated once the compressor has altogether been  
     switched on for time d0  
2 = AT INTERVALS ‐ FOR EVAPORATOR TEMPERATURE ‐ defrost will be activated when the evaporator temperature has  
      remained below the temperature d9 for a total time of d0 (11)  
3 = ADAPTIVE ‐ defrost will be activated at intervals, whose duration will each time depend on the duration of compressor  
      switch‐ons, the evaporator temperature and the door switch input activation; see also d18, d19, d20, d22, i13 and i14 (11)  

d9  

‐99 

99 

°C/°F (1)  

evaporator temperature is higher than that at which the defrost interval counter is suspended (only if d8 = 2)  

d11  

‐‐ 

defrost alarm switches off once maximum time limit has been reached (code “

dFd

"

; only if P3 = 1 and in absence of 

evaporator probe error (code “

Pr2

"

)  

1 = YES  

d15  

99 

min  

10 

10 

10 

10 

minimum time that the compressor must be switched on before defrost can be activated (only if d1 = 1) (12)  

d16  

99 

min  

pre‐dripping duration (during dripping the compressor will remain switched off, the defrost output will be activated and the 
evaporator fan shall remain off)  

d18  

999 

min  

40 

defrost interval (defrost will be activated when the compressor has been on totally, with the evaporator temperature below 
that of d22, for time d18; only if d8 = 3)  
0 = defrost will never be activated due to the effect of this condition  

d19  

40 

°C/°F (1)  

evaporator temperature below which the defrost is activated (relative to the evaporator temperatures average, or 
“evaporator temperatures average ‐ d19”; only if d8 = 3)  

d20  

999 

min  

180 

minimum consecutive time the compressor must be switched on such as to provoke the defrost activation  
0 = defrost will never be activated due to the effect of this condition  

d21  

500 

min  

200 

200 

200 

200 

200 

minimum duration of compressor continuous operation from the switching on of the device (provided that the "cell 
temperature ‐ working setpoint" or "CPT temperature ‐ working setpoint" difference exceeds 10 °C/20 °F) and from the 
activation of the "rapid cooling" function so as to start the defrost  
0 = defrost shall never be activated as a consequence of this condition  

d22 

19,9 

°C/°F (1)   

evaporator temperature above which the defrost interval count shall be suspended (relating to the average of evaporator 
temperatures, that is to say, "evaporator temperatures a d22”; only if d8 = 3); see also d18  

 
PARAM.   MIN.  

MAX.  

U.M.  

DEF.  

GRAM FG 

HAV 

GRAM KG 

HAV 

GRAM FG 

FAV 

GRAM KG 

FAV 

TEMPERATURE ALARMS  

Summary of Contents for Eco Euro KG 60

Page 1: ...765041996 Rev 001 1 Operating and servicemanual Eco Midi KG FG 60 82...

Page 2: ...g the product 3 Temperature setting 4 Keyboard lock 4 Alarms 5 Error codes on the display 6 Defrosting 7 Setting the configuration parameters 8 Manufacturer s settings 9 Working setpoint and configura...

Page 3: ...this is indicated by a small control lamp which is the only one lit in the lower right corner of the display To switch the product on press for approx 3 seconds During start up the control lamp will b...

Page 4: ...mpressor is running Alternatively by not touching the keys for a minimum of 15 seconds the controls will switch back to the normal temperature display and the value that has been set will be saved aut...

Page 5: ...is shown in the display if the condenser temperature has been too high Clean the condenser filter in front of the condenser Refer to the placement of the filter in Fig 3 CSd Compressor shut off This...

Page 6: ...Control lamp for defrosting Lit continuously during defrosting Blinks while draining after completed defrosting Control lamp for evaporator fan Lit continuously when the evaporator fan is in operatio...

Page 7: ...ng is automatically performed 4 times every 24 hours by a defrost heating element Manual defrosting If the cabinet is operating under severe load frequent door opening and frequent replenishment manua...

Page 8: ...765041996 Rev 001 8 Setting the configuration parameters...

Page 9: ...765041996 Rev 001 9 Manufacturer s settings...

Page 10: ...t air temperature 4 if P4 0 1 o 2 if P4 3 inlet air temperature P7 0 100 50 50 50 50 50 inflowing air temperature percentage for the calculation of the CPT temperature P8 0 250 0 1 s S 100 100 100 100...

Page 11: ...d16 0 evaporator fan activity will depend on F2 parameter if d16 0 the evaporator fan shall remain off d8 0 3 0 0 0 0 0 defrost activation methods 0 AT INTERVALS FOR TIME defrost will be activated on...

Page 12: ...aporator fan operation when the compressor is turned off see also F7 only if F0 2 PARAM MIN MAX U M DEF GRAM FG HAV GRAM KG HAV GRAM FG FAV GRAM KG FAV DIGITAL INPUTS i0 0 5 5 2 2 2 2 effect caused by...

Page 13: ...w consumption function is activated 0 the mode shall never be aactivated PARAM MIN MAX U M DEF GRAM FG HAV GRAM KG HAV GRAM FG FAV GRAM KG FAV VARIOUS key activation POF 0 1 1 1 1 1 1 1 YES PAS 99 999...

Page 14: ...condenser temperature falls below the value set with parameter F11 provided that the compressor is switched off 22 the compressor is switched off 10 s after the activation of the input if the input i...

Page 15: ...765041996 Rev 001 15 Wiring diagram...

Reviews: