GrainPro MA4068RAD0718-1 Instruction Manual Download Page 4

      

      4/25 

 

 

GrainPro

®

 Carbon Dioxide Analyzer Instruction Manual   

MA4068RAD0718 - 1 

 

 

2. 

CHECKLIST 

 
Please inspect your GrainPro

®

 CO

2

 Analyzer package to ensure it includes the following items: 

 

PART NAME 

DESCRIPTION 

IMAGE 

2.1.  CO

2

 Analyzer 

2.1.1.   CO

2

 Analyzer, 0-80% 

range, IR sensor with 
Rechargeable Battery (7.4 
V/1500 mAH Li-ion) 

 

 

 

 

 

 

2.2.  Battery Charger 

2.2.1.  Battery Charger, 

110V/250VAC with 4 
different types of 
interchangeable plugs. 

 

 

 

 

 

 

 

2.3.  Sampling Tubes with 

dust filter 

2.3.1.  Sampling tube, 40cm with 

dust filter for inlet 

 

2.3.2.  Sampling tube, 40cm with 

dust filter for outlet 

 

 

2.4.  Screwdriver 

2.4.1.  Double ended screwdriver. 

 

 

 

 

Summary of Contents for MA4068RAD0718-1

Page 1: ...GRAINPRO CARBON DIOXIDE ANALYZER INSTRUCTION MANUAL MA4068RAD0718 1...

Page 2: ...CEDURES 8 5 1 Power On 8 5 2 Initialization 8 5 3 Setting Mode 9 5 4 Sampling Mode 9 5 5 Download Reset Mode 11 5 6 Monitoring Battery Charge 20 5 7 Calibration Mode 20 6 USING CARBON DIOXIDE ANALYZER...

Page 3: ...ack It is powered by a 7 4V Li ion rechargeable battery 1 1 FEATURES 1 1 1 Portable 1 1 2 More than 5 years sensor expected life span 1 1 3 Backlit 20 x 4 Alphanumeric OLED display 1 1 4 Microprocesso...

Page 4: ...MAGE 2 1 CO2 Analyzer 2 1 1 CO2 Analyzer 0 80 range IR sensor with Rechargeable Battery 7 4 V 1500 mAH Li ion 2 2 Battery Charger 2 2 1 Battery Charger 110V 250VAC with 4 different types of interchang...

Page 5: ...CO2 Analyzer to a computer 2 6 USB Flash Drive 2 6 1 USB Flash drive includes a Software b CO2 Analyzer Instruction Manual c Instruction Video d GP Audio Visual Presentation e Flyer All GP Products 2...

Page 6: ...Dioxide Analyzer Instruction Manual MA4068RAD0718 1 2 9 Instruction Manual 2 9 1 Instruction manual for CO2 Analyzer 3 COMPONENTS COMPONENTS DESCRIPTION FUNCTION Figure 1 Carbon Dioxide Analyzer Batte...

Page 7: ...s placed d Settings Mode Key is where setting and Turn off are located In Setting this Key is used to increase the value of the digit on which the cursor is placed e Download Reset Mode In this mode y...

Page 8: ...8 Display It is a 20 x 4 alphanumeric OLED display which indicates a Various prompts during initialization process immediately after turning ON the CO2 Analyzer b CO2 concentration Date and Time in t...

Page 9: ...ll Scale range but also depends on the accuracy of the calibrating gas method Battery 7 4 V 1500 mAH Li ion Rechargeable Battery Charger Input 100 240V 50 60Hz 0 6A Max Output 8 4V 10A Operating Tempe...

Page 10: ...charger before using the device NOTE Charge until the Red LED on the charger turns Green See section 5 6 3 5 1 2 After fully charge press and hold the Set Key for 3 4 seconds 5 1 3 Green LED marked PO...

Page 11: ...DN Key for Calibration c SET Key for Settings d ENT Key for Download Reset 5 3 Setting Mode 5 3 1 Accessing parameter setting mode a From the Main Menu press the SET Key to enter into the setting page...

Page 12: ...for increasing the value 0 to 9 and Down Key to shift the cursor Then press ENT Key to confirm d To change Date and Time use Up Key for increasing the value 0 to 9 and Down Key to shift the cursor Th...

Page 13: ...s from the surrounding environment 5 4 5 If the Sampling mode is selected a CO2 analyzer will display prompt to verify if the tubes were already removed b Press Enter Key to start Zero Check about 7 s...

Page 14: ...ift 8 5 5 5 Download Reset Mode 5 5 1 INSTALLATION AND DOWNLOADING FOR WINDOWS 5 5 1 1 Software Installation for Windows a Install Uniphos Terminal Software from USB Flash drive provided along with th...

Page 15: ...Driver go back to the USB Flash drive files and open the MY_TERMINAL_V_1 1 folder i Open the Volume folder and Install the application 5 5 1 2 Download Data for Windows a After the installation short...

Page 16: ...com port number search for Device Manager Go to Ports COM LPT click on the drop down list and get the com port number e Go back to the Uniphos Terminal Window and select the com port number NOTE Gener...

Page 17: ...summary or range of reading on your computer press Up Key i While downloading number of readings will also appear on the screen j Summary of data will be displayed on the Uniphos Terminal on your comp...

Page 18: ...1 5 5 2 1 Software Installation for Linux a Install gtkterm from Ubuntu Software on your computer b Open Ubuntu Software c On the search bar type gtkterm d Click on the Serial Port Terminal gtktern an...

Page 19: ...al and check USB Serial port connection b While the CO2 Analyzer is not connected type the command dmesg grep tty on the terminal c No USB connection shall appear d Connect the CO2 Analyzer with your...

Page 20: ...connection of your CO2 Analyzer Baud Rate 9600 Parity none Bits 8 Stopbits 1 other parameters as default Click OK after h Next click on Log from the menu and choose to file i Window for saving files w...

Page 21: ...nloading of the data to the terminal software is done go back to Control Signals and click Close Port n Check on the Log file data You can open either with Text Editor or any spreadsheet app on Linux...

Page 22: ...NSTALLATION AND DOWNLOADING FOR MAC 5 5 3 1 Software Installation for MAC a Open MAC Folder from USB Flash Drive provided along with the CO2 Analyzer b Open FTDI USB DRIVER folder c Choose driver matc...

Page 23: ...3 25 GrainPro Carbon Dioxide Analyzer Instruction Manual MA4068RAD0718 1 e Installation window will appear after Just click on continue and install f Go Back to MAC folder and choose TERMINAL SOFTWARE...

Page 24: ...pen dmg file h Window from dmg file will appear Click on CoolTerm after i CoolTerm software will appear 5 5 3 2 Download Data for MAC a Open MAC s Terminal to check USB Serial port connection b While...

Page 25: ...r via USB Cable provided e In the terminal type again the command ls dev tty USB connection shall appear on the terminal f Open CoolTerm software again g From the menu click Options h From the Serial...

Page 26: ...om the Main Menu j Choose Capture to Textfile from the drop down list and click Start k Window Select a filename and destination for the capture data will appear Create a file and Save l After setting...

Page 27: ...close CoolTerm p Check on the saved capture data You can open either with TextEdit or MAC iWork s Numbers or other file viewing app 5 5 4 Erase Data on CO2 Analyzer a Press the Down Key to erase all t...

Page 28: ...to main Menu 5 6 Monitoring Battery Charge 5 6 1 Battery Status Battery status can only be monitored when the CO2 Analyzer is in the Data downloading page 5 6 2 Battery Low When the battery capacity g...

Page 29: ...ion mode b Enter the Password 321 and expose to ambient air or connect to pure nitrogen c Press Enter Key to confirm then the CO2 Analyzer is ready for Zero calibration d The Apply Zero Gas prompt wil...

Page 30: ...ompt will appear on screen and will ask for Span Gas Value j CO2 Analyzer will be calibrated only if counts value for applied span gas is within valid range i e from 1000 to 4030 display counts ideall...

Page 31: ...or damages CO2 level of ambient air is 0 03 to 0 04 7 MAINTENANCE AND CARE 7 1 Do a regular monthly battery checkup and recharge it fully before use Charge the instrument until Red LED on charger turn...

Page 32: ...bnormal noise There may be a blockage in the gas sampling tube or in the nozzles Clear blockage 8 4 The instrument does not turn On Low battery Recharge Battery 8 5 Sensor Drift Count value is lower t...

Page 33: ...ked just input continuously and press enter again 4 To add dialout type in the command sudo usermod a G dialout USERNAME and press enter 5 Type in the command group again Notice if tty and dialout is...

Page 34: ...red light dispersed according to its wavelength sensor often used as a gas detector It is nondispersive in the sense of optical dispersion since the infrared energy is allowed to pass through the atmo...

Page 35: ...parts thereof if the defect is a result of any of the following normal wear and tear damages occurring after delivery accidents acts of God or catastrophes fault or negligence or improper storage ins...