background image

Error! Main Document Only.-8 

 Alignment

D/ESAM 820 User’s Guide

Monitor Output Adjustments

The following procedure is specific to the analog Monitor output only and assumes
that meters are aligned correctly.

1.

Assign a source with reference tone to all four D/ESAM Program buses.
In Chapter 3, refer to the “Channel Assignment” section for
instructions on Channel Assignment and the “Manual Program /
Preset Configuration
” section for details on Program / Preset
Configuration.

2.

In the Monitoring Section, enable 

MON 1

, 

2

, 

3

4

 and 

MIX OUT

.

Ensure that 

PGM 

is selected in the Program / Preset section.

3.

Bring up the fader(s) so that meters read 0VU (-8PPM).

4.

Ensure that 

MONO

2-CH

 and 

LEVEL/BAL 

indicators are OFF.  In

addition, ensure that Monitor Sub-mix mode is OFF.  In Chapter 3,
refer to the “Monitoring” and “Monitor Sub-mix Mode” sections for
more details.

5.

Turn both rotary knobs clockwise until the Monitor outputs are at their
maximum output level.

6.

Adjust each Monitor output gain trim to match the monitor amplifier’s
input sensitivity.  The location of the Monitor trims are indicated in the
figure above.

NOTE

The internal tone generator can be used for alignment.  In Chapter 5, see the
Alignment - Menu 6.1” section for setting tone generator options.

Summary of Contents for D/ESAM 820

Page 1: ...hem to their uppermost limit 6 dB position Leave each fader there 3 To align faders press LOCK UNLK hold it down and press FADER SPLIT Electrical position now matches the physical scale printed on the...

Page 2: ...operating level of 10dBu to 14dBU Operating levels are changed by replacing resistor networks socketed which are available from GPS Use the table below to select the appropriate resistor network Anal...

Page 3: ...be tested 3 Select R in the Preview Section on the Control Panel and assign virtual machine which contains the inputs to be aligned to R Refer to the Machine Assignment section in Chapter 3 for machi...

Page 4: ...CONTROL ADDRESS BLOCK AUDIO ADDRESS BLOCK SYNC ASYNC 110 250 SYNC ASYNC 110 250 SYNC ASYNC 110 250 SYNC ASYNC 1J1 1J3 2J1 2J3 3J1 3J3 4J1 4J3 e AES Input Module Assy 04 0164 00 The Digital AES Input...

Page 5: ...SAM 820 Series module definition 04 0167 XX is compatible with any of the previous versions of the digital input modules 04 0148 00 or 04 0141 00 Jumper Settings The module has two sets of jumpers for...

Page 6: ...on below for the following adjustment procedures 1 2 3 2 3 AUDIO OUTPUT MODULE 04 0130 4 4 3 3 2 2 1 1 4 3 2 1 PROGRAM METER MONITOR R511 R510 R611 R610 5 GND 5 15 15 Program Output Gain Trims Meter O...

Page 7: ...ccidental adjustments NOTE The internal tone generator can be used for alignment In Chapter 5 see the Alignment Menu 6 1 section for setting tone generator options Program Output Adjustments The follo...

Page 8: ...d MIX OUT Ensure that PGM is selected in the Program Preset section 3 Bring up the fader s so that meters read 0VU 8PPM 4 Ensure that MONO 2 CH and LEVEL BAL indicators are OFF In addition ensure that...

Reviews: