Error! Main Document Only.-8
•
Alignment
D/ESAM 820 User’s Guide
Monitor Output Adjustments
The following procedure is specific to the analog Monitor output only and assumes
that meters are aligned correctly.
1.
Assign a source with reference tone to all four D/ESAM Program buses.
In Chapter 3, refer to the “Channel Assignment” section for
instructions on Channel Assignment and the “Manual Program /
Preset Configuration” section for details on Program / Preset
Configuration.
2.
In the Monitoring Section, enable
MON 1
,
2
,
3
,
4
and
MIX OUT
.
Ensure that
PGM
is selected in the Program / Preset section.
3.
Bring up the fader(s) so that meters read 0VU (-8PPM).
4.
Ensure that
MONO
,
2-CH
and
LEVEL/BAL
indicators are OFF. In
addition, ensure that Monitor Sub-mix mode is OFF. In Chapter 3,
refer to the “Monitoring” and “Monitor Sub-mix Mode” sections for
more details.
5.
Turn both rotary knobs clockwise until the Monitor outputs are at their
maximum output level.
6.
Adjust each Monitor output gain trim to match the monitor amplifier’s
input sensitivity. The location of the Monitor trims are indicated in the
figure above.
NOTE
The internal tone generator can be used for alignment. In Chapter 5, see the
“Alignment - Menu 6.1” section for setting tone generator options.