INTRODUCTION
This manual contains assembly, operation, and maintenance instructions for Lumex Ortho-Biotic II
Recliners series FR597G (FR597G, FR597GH, and FR597GHO) and FR597P (FR597P, FR597PH, and
FR597PHO). Read the entire manual carefully before using your recliner, and refer to it during use if
you have questions. If you have further questions, call GF Health Products, Inc. / Lumex Technical
Support at 1.770.368.4700.
INTENDED USE
The Lumex Ortho-Biotic II Recliner Series FR597 is intended to make the care, treatment and
recovery of patients easier and more comfortable. Lumex Healthcare Seating is used in a wide
range of healthcare applications including Patient Room, Same Day Surgery, Post-Anesthesia
Recovery, Oncology / IV Therapy, Dialysis and Patient Transport. Lumex Healthcare Seating is
ideal for use in hospitals, clinics, surgery centers, and rehabilitation centers.
Lumex Ortho-Biotic II Recliner Series FR597 supports patient weights up to 350 lb (159 kg) when
EVENLY DISTRIBUTED
.
IMPORTANT SAFETY PRECAUTIONS—READ BEFORE USE
The safety statements presented in this chapter refer to the basic safety information that the
Series FR597 user must pay attention to and abide by. There are additional safety statements in
other chapters or sections, which may be the same as or similar to the following, or specific to
the operations. Note the following special statements, used throughout this manual, and their
significance:
WARNING: Indicates a potential hazard situation or unsafe practice that, if not avoided,
could result in death or serious personal injury.
CAUTION: Indicates a potential hazard or unsafe practice that, if not avoided, could result
in minor or moderate personal injury.
s
NOTICE: Indicates a potential hazard or unsafe practice that, if not avoided, could result in
product or property damage.
Info: Provides application recommendations or other useful information to ensure that you get
the most from your product.
WARNINGS
WARNING: Read this entire manual before assembly or operation.
WARNING: Periodically inspect all parts and replace as needed.
WARNING: Do not use near an open flame, as the chair could be a combustion source,
resulting in fire, property damage, and severe personal injury.
WARNING: Service and repair of the Lumex FR597 Ortho-Biotic II Recliner must be
performed by an authorized Lumex distributor. GF Health Products, Inc. is not responsible
for any consequence resulting from any unauthorized service or repair.
WARNING: This product has a maximum weight capacity of 350 lb (159 kg), EVENLY
DISTRIBUTED.
WARNING: Casters must be locked at all times, except during transport.