background image

Summary of Contents for Plumbworld Ultraflow Macerator

Page 1: ...plumbw I Ultraflow Macerator Instruction Manual rid Please keep this instruction manual for future reference C Grafton Group PLC Page 1 of20...

Page 2: ...tion 3 Safety Instructions 4 Product Description 5 Operating Principle 6 Parts Listing 7 Installation 8 Troubleshooting 9 Clearing Blockages 10 Clearing a Pressure Tap Chamber Blockage 11 Replacing th...

Page 3: ...low Macerator product is in conformity with the following directives to specification under which conformity is declared The Low Voltage Directive Directive 2006 95 EC EMC Directive Directive 89 336 E...

Page 4: ...Discharge head 6mws Capacitor 10uF 450 Volts Water Ingress Protection IPX4 Flow rate at pump output 270 litres minute Maximum discharge height 5 5 metrest Maximum discharge horizontal length 60 metres...

Page 5: ...door use only The appliance is suitable for the discharge of domestic faecal matter waste water and toilet paper only Failure to comply with this will invalidate the warranty Products not to be discha...

Page 6: ...the appliance Failure to carry out regular maintenance and servicing of the appliance as detailed in these instructions 4 PRODUCT DESCRIPTION The Ultraflow Macerator is designed for the purposes ofdis...

Page 7: ...uated Domestic waste is collected in the tank A The air chamber B records the air pressure flowing through the outlet pipe C to the pressure switch D The pressure switch D trips the motor E The motor...

Page 8: ...ppliance is also supplied 8 Mechanical Seal with the following spare parts 9 Open Impeller 10 Injector 3 x clamping ring 11 Outlet Pipe 3 x blanking caps 12 Cable and Plug 2 x check valve 13 Cable Gla...

Page 9: ...Green Yellow Earth 4 Fit a 5 Amp fuse to the fused connection unit 5 THIS APPLIANCE MUST BE EARTHED HYDRAULICS The macerator is only compatible for use with a toilet with a horizontal outlet It must...

Page 10: ...ip ensuring it is fully tightened 1 Place the horizontal toilet outlet inside the rubber sleeve of the macerator Clamp the outlet and sleeve using one of the jubilee clips supplied 2 Place the dischar...

Page 11: ...e diagram below 30 l Macerator Check Valve pipe work is fully seated into both the Macerator and the check valve An arrow on the side of each check valve indicates the correct direction of frtment If...

Page 12: ...ure to install the appliance with the correct gradient will prevent waste from being discharged If used with a shower the second check valve must also be used This must be fitted between the shower tr...

Page 13: ...for at least 30 switched itself off overheated This has minutes Switch it back on Press and activated the thermal hold the override switch for at least 30 cut out switch seconds This will reset the m...

Page 14: ...reset the unit direction Check the pressure switch and replace if The pressure switch is necessary partially blocked The pressure switch has developed a fault The macerator is not The discharge pipes...

Page 15: ...ge A partial blockage in the pressure valve tube is causing the macerator Check the pressure switch Replace if to think water is inside necessary the unit There is a pressure switch defect The macerat...

Page 16: ...ck valve Check the pressure switch and replace if necessary There is a defect with Check the vertical tube inside the sealed the pressure switch rubber chamber Ensure this is not blocked The pressure...

Page 17: ...the hose clips with pliers Disconnect the inlet and outlet connections 4 Loosen the large hose clip securing the unit to the pan Detach the appliance 5 Remove the lid from the appliance by undoing the...

Page 18: ...Locate the plug on the top of the main tank Fig 1 2 Loosen the hose clip with pliers At the same time remove the plug from the top ofthe pressure tap chamber Fig 2 3 Examine the end of the plug to en...

Page 19: ...remove the air switch from inside Fig IV 6 Remove the replacement air switch from its packaging and locate the spigot This will project from the main body of the switch 7 Insert the spigot into the e...

Page 20: ...EC and must be handled in accordance with these standards at the end of its service life Customer Care Helpline Our customer care centre can be contacted during normal working hours For spare parts a...

Page 21: ...ut our full range of macerators Saniflo Macerators Flo Force Macerators Stuart Turner Macerators Grundfos Macerators Don t Forget These Macerator Accessories from Saniflo Saniflo Sani Alarm Saniflo De...

Reviews: