background image

Siphon

790

80

Fließrichtung

270

620

110

110

110

365

270

Zulauf

Ablauf

Tank

Siphon

790

80

Fließrichtung

270

620

110

110

110

365

270

Zulauf

Ablauf

Tank

Siphon

790

80

Fließrichtung

270

620

110

110

110

365

270

Zulauf

Ablauf

Tank

Siphon

790

80

Fließrichtung

270

620

110

110

110

365

270

Zulauf

Ablauf

Tank

Siphon

790

80

Fließrichtung

270

620

110

110

110

365

270

Zulauf

Ablauf

Tank

 

3.  Technical data 

3.1  Dimensions with curved outlet 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

inlet 

outlet 

 

flow direction 

tank 

Summary of Contents for 340093

Page 1: ...downloaded on www graf info or can be requested from GRAF Table of contents 1 General notes 11 1 1 Safety 11 2 Installation conditions 11 2 1 MINIMAX PRO Filter internal 11 3 Technical data 12 3 1 Dimensions with curved outwith curved outlet 4 Technical data 13 4 1 Dimensions straight outlet 13 5 Assembly 14 5 Installation and assembly 14 5 1 Overview Platin tank Filter with curved outlet 14 5 2 I...

Page 2: ...ut on parts of the system or the system Except when working in the tank the tank cover must always be kept closed due to acute danger of accident GRAF offers an extensive range of genuine parts accessories all of which are designed to ensure the system performs as specified The use of non genuine Grafparts or accessories may lead to the system s functional capability or failure therefore invalidat...

Page 3: ...10 365 270 Zulauf Ablauf Tank Siphon 790 80 Fließrichtung 270 620 110 110 110 365 270 Zulauf Ablauf Tank Siphon 790 80 Fließrichtung 270 620 110 110 110 365 270 Zulauf Ablauf Tank Siphon 790 80 Fließrichtung 270 110 365 270 Ablauf 3 Technical data 3 1 Dimensions with curved outlet inlet outlet flow direction tank ...

Page 4: ...00 110 110 365 Zulauf Ablauf Tank 110 10 500 Fließrichtung 270 500 110 110 365 270 Zulauf Ablauf Tank 110 10 500 Fließrichtung 270 500 110 110 365 270 Zulauf Ablauf Tank 110 10 ung 270 365 270 Ablauf 110 10 3 Technical data 3 2 Dimensions with straight outlet inlet outlet Flow direction tank ...

Page 5: ...85 265 4 Assembly Clear transparent cover Filter insert Housing including nozzle holder Outlet bend 87 Optional cleaning unit 340040 5 Installation and assembly 5 1 Overview Platin tank Filter with curved outlet ...

Page 6: ... from outside 5 3 Preparation filter for installation Connect the filter body with a PVC pipe DN 100 on site with the inflow Calming Foot contained in filter package 342038 Secure or connections with Self Tapping screws to prevent connections separating Platin tank 1500 L 3000 L 5000 L 7500 L L 470 mm 500 mm 675 mm 1075 mm 5 Installation and assembly 10 mm ...

Page 7: ... tank Slide the outlet bend of the filter into the overflow siphon from above align the supply pipe flush with the filter and then fix with the quick connection sleeve included in filter package 342038 5 Installation and assembly 5 5 Overview of Carat tank filter with straight outlet 5 Installation and assembly ...

Page 8: ...DN100 from outside 5 7 Preparation filter for installation Connect the filter body with a PVC pipe DN 100 on site with the inflow Calming Foot contained in filter package 340119 Fix all junctions with screws against shift of pipes Carat tank 2700 L 3750 L 4800 L 6500 L 8500L 10000 L L 1190 mm 1380 mm 1610 mm 1890 mm 1790 mm 1990 mm 5 Installation and assembly 10 mm ...

Page 9: ...nt guards should never be installed in the Filter outlet as this could cause dirt to enter the drain and block the pipe Handle XL for MINIMAX PRO Filter Order No 330220 Depending on the dirtiness of the roof surface water the sieve has to be cleaned several times a year Remove the transparent cover from the filter body The sieve and the cover is one unit Removing and cleaning is unproblematic 5 In...

Reviews: