Section 3 - Operation
3-2
82104002
Preparing Upperstructure for Remote Control Operation
All instructions on undercarriage cab remote control decal must be followed before
starting machine in remote operation.
1. Place control cut out lever in locked/inactive position (refer to page 2-19).
2. Turn ignition switch to “RUN” position.
3. The wait-to-start light will illuminate on LCD Display. When light turns off, move
to step 4.
Note: Engine will not start when light is illuminated.
4. Turn ignition switch to “START” position to start engine. If engine fails to start,
turn ignition switch to “OFF” position and return to step 2.
5. Position control cut out lever in the unlocked/active position to activate and
engage joystick controls and pedals in remote operation.
OAC2260