Before Beginning Repair
3A2798D
13
Before Beginning Repair
Maintenance Procedures
Platen Maintenance
See F
IG
. 10. If the platen does not come out of the pail
easily when the pump is being raised, the air assist
tube (EF) or air assist check valve may be plugged, or
the bleed stick (J) may not be tightened. A plugged air
assist check valve prevents air from reaching the under-
side of the plate to assist in raising it from the pail. If the
bleed stick is not tightened no pressure will build.
1.
Follow the
on page 10.
Refer to platen parts illustration on page 28 and dis-
assemble air assist check valve (414) as shown.
2.
Clear air assist tube (EF) in platen. Clean all parts of
air assist check valve (414) and reassemble.
3.
Remove bleed stick (J) from platen. Push bleed
stick through bleed relieve ports to remove material
residue.
Adjust Spacers
Use Platen with Tapered and Straight Sided
Pails
Use platen with tapered pails
1.
Working from the bottom
, use screwdriver to pry
spacer (EG) loose. Work spacer upward completely
above the flange of the platen. See F
IG
. 11.
2.
By hand, angle spacer (EG) and work it off the plate,
pulling it down over the flange. See F
IG
. 12.
3.
Save spacer (EG), as it is required for other applica-
tions.
To reduce the risk of serious injury whenever you are
instructed to relieve pressure, always follow the
Pressure Relief
procedure.
F
IG
. 10
EG
EF
ti20250b
EK
F
IG
. 11
EG
EB
ti20251b
Summary of Contents for Xtreme PFP 16P957
Page 33: ...Notes 3A2798D 33 Notes...