Setup
3A6283F
25
Connect Power Source
NOTE:
Required voltage and amperage is noted on the
control panel label. See
below.
Use the intended entry locations shown in
1. Turn the main power switch (MP) off.
2. Open the junction box door.
3.
Non-Hazardous Locations only:
Route the power
cord through the strain relief (ZH) into the electrical
enclosure (ZC).
Hazardous Locations only:
Follow local codes
and regulations for routing the power through the
main power entry point (ZS).
NOTE:
The machine is provided with jumpers in the 380
Vac 3-Phase Wye position.
NOTE:
Terminal jumpers are not used for 480V.
4. Connect the ground wire to the ground terminal (G).
5. Connect the power cord to the disconnect as shown
in
all connections to verify that they are properly
secured.
6.
Non-Hazardous Locations only:
Tighten the strain
relief (ZH).
Hazardous Locations:
Follow local codes and
regulations for sealing the power cable entering into
the enclosure.
7. Install the supplied terminal jumpers in the positions
8. Verify that all items are connected properly as
then close the electrical enclosure (ZC) door.
Power Cord Guidelines
Use the guidelines listed in the table below to determine the power cord needed for your specific system.
To help prevent injury from electric shock, turn off and
disconnect power at the main switch before
connecting any cables and before servicing
equipment. All electrical work must be done by a
qualified electrician and comply with local codes and
regulations.
Models with 240 Volt Viscon HF Fluid Heater
Junction Box
Full Load Peak Amperes (A)
xxxx01
xxxx11
xxxx02
xxxx12 xxxx03 xxxx13
240 V, 1 Phase
87
87
71
71
84
84
240 V, 3 Phase
76
76
65
65
73
73
380 V, 3 Phase
48
48
48
48
48
48
480 V
Models with 480 Volt Viscon HF Fluid Heater
Junction Box
Full Load Peak Amperes (A)
xxxx21
xxxx31
xxxx22
xxxx32 xxxx23 xxxx33
240 V, 1 Phase
240 V, 3 Phase
380 V, 3 Phase
480 V
28
28
26
26
27
27
Summary of Contents for XP50s-hf
Page 61: ...Parts 3A6283F 61 XP50s hf and XP70s hf Proportioners Continued WL F ...
Page 64: ...Parts 64 3A6283F Water Jacketed Heated Hose Packages WL D 2 2 2 247 246 245 ...
Page 66: ...Parts 66 3A6283F Non Heated Hose Packages WL D 2 2 ...
Page 68: ...Parts 68 3A6283F Non Hazardous Location Electric Heated Hose Packages WL D 480V 240V ...
Page 69: ...Parts 3A6283F 69 Hazardous Location Electric Heated Hose Packages WL D 9 9 ...
Page 82: ...Dimensions 82 3A6283F Dimensions System Dimensions WL D LQ FP LQ FP LQ FP Top View Side View ...