Repair
3A6283F
57
Remove Motor
1. Flush all system components. Follow the complete
procedure starting on page 44.
2. Disconnect the air line from the air motor.
3. Remove the air motor rod cover (921) and pump
guards (922).
4. Use a wrench to hold the tie rod (902) flats to keep
the rods from turning. Unscrew the nuts (908) from
the tie rods.
5. Place a wrench on the motor shaft hex flats (HX).
Loosen coupling nut (909).
6. Use a hoist to remove the air motor by the lift ring.
7. Refer to the air motor manual to service or repair the
air motor.
Recirculation Manifold with Over
Pressure Relief Valves
1. Flush all system components. Follow the complete
procedure starting on page 44.
2. Disconnect all fluid hoses from the material
recirculation manifold (35).
3. Remove the mix manifold if it is assembled to the
material recirculation manifold.
4. Loosen the two screws (37) that secure the manifold
(35) to the cart (1).
5. Remove the two screws (37) and material
recirculation manifold (35) from the cart (1).
WLD
921
922
WLD
902
908
HX
909
WLD
37
35
1
Summary of Contents for XP50s-hf
Page 61: ...Parts 3A6283F 61 XP50s hf and XP70s hf Proportioners Continued WL F ...
Page 64: ...Parts 64 3A6283F Water Jacketed Heated Hose Packages WL D 2 2 2 247 246 245 ...
Page 66: ...Parts 66 3A6283F Non Heated Hose Packages WL D 2 2 ...
Page 68: ...Parts 68 3A6283F Non Hazardous Location Electric Heated Hose Packages WL D 480V 240V ...
Page 69: ...Parts 3A6283F 69 Hazardous Location Electric Heated Hose Packages WL D 9 9 ...
Page 82: ...Dimensions 82 3A6283F Dimensions System Dimensions WL D LQ FP LQ FP LQ FP Top View Side View ...