Appendix A - User Interface Display
84
3A2776H
Supply Screen
Use these screens to turn on and off automatic tank fill-
ing, turn on and off the fluid heaters and hose heat, and
change temperature setpoints for each fluid heater and
for the hose heat.
When automatic tank filling is on, the feed pump will
begin pumping fluid into the tank when the fluid level
goes below the bottom arrow. It will continue filling until
the fluid level reaches the upper arrow. When the feed
pump is running, the small circle on the screen next to
the tank will have a black background. In order for auto-
matic tank filling to run, the director valve (3DC) must be
in the DOWN position, and the RAM slider valve (DA)
and air motor slider valve (DF) must both be in the ON
position with proper air pressure air supplied to the RAM
and air motor. See Feed Pump Air Controls on
page 14.
This screen also displays the current volume of each
tank and the current temperature measured at each fluid
heater, at the hoses, and in each tank.
Press
to three times display additional information.
Icon
Function
Turn on and off automatic tank filling
Turn on and off the A fluid heater
Turn on and off the B fluid heater
Turn on and off the hose heat
Additional
Information
1
Tank level sensor A (volts)
2
Tank level sensor B (volts)
3
Water/glycol mixture temperature at heater
1
2
3