Flat Spray Tips
312666W
19
Flat Spray Tips
1. Follow
2. Unscrew and remove front cover retainer
(C).
3. Remove front cover (U) and o-ring (2b).
Inspect o-ring.
4. Remove tip retainer (46) and tip (21).
Inspect o-ring (47).
5. Remove fluid housing (F). Loosen A and B
side seals. Slide flat mix chamber (14) out
rear of fluid housing.
NOTE:
If tip is stuck, pry off with small screw-
driver or pull off with pliers. Tip is hardened to
resist damage.
6. To clean, soak tip in compatible solvent.
Clean gently with tip cleanout tool 15D234;
page 56 for details of tool.
7. Reassemble in reverse order.
a. Insert mix chamber (14) from rear of
fluid housing.
b. Tighten A and B side seals on fluid
housing.
c. Assemble o-ring (47), tip (21), and tip
retainer (46) to front of mix chamber
(14).
8. Reposition tip horizontally or vertically, or
install different tip size.
NOTE:
Tips marked on back with last three
digits of part number. See
9. Reinstall fluid housing (F) to handle.
10.Reinstall front cover (U) and front cover
retainer (C).
F
IG
. 22
C
U
F
TI12087a
14
47
21
46
F
IG
. 23
TI12088a
TI2648a