Technical Data
Electrostatic Air—Assisted Spray Waterborne Guns
U.S.
Metric
Maximum Working Fluid Pressure
3000 psi
21 MPa, 210 bar
Maximum Working Air Pressure
100 psi
0.7 MPa, 7.0 bar
Minimum Air Pressure at Gun Inlet
45 psi
0.32 MPa, 3.2 bar
Maximum Fluid Operating
Temperature
120°F
48°C
Short Circuit Current Output
125 microamperes
Voltage Output Energy
0.35 J with fluid hose 24M508 installed.
H60T18: 60 kV
H60M18: 30–60 kV
Sound Power (measured per ISO
Standard 9216)
at 40 psi: 90.4 dB(A)
at 100 psi: 105.4 dB(A)
at 0.28 MPa, 2.8 bar: 90.4 dB(A)
at 0.7 MPa, 7.0 bar: 105.4 dB(A)
Sound Pressure (measured 1 m from
gun)
at 40 psi: 87.0 dB(A)
at 100 psi: 99.0 dB(A)
at 0.28 MPa, 2.8 bar: 87.0 dB(A)
at 0.7 MPa, 7.0 bar: 99.0 dB(A)
Air Inlet Fitting
1/4 npsm(m) left-hand thread
Fluid Inlet Fitting
Custom inlet for Graco waterborne fluid hose.
Isolation Enclosure Air Inlet Fitting
1/4 npt
Isolation Enclosure Fluid Inlet Fitting
3/8 in. OD tube fitting
10 mm OD tube fitting
Wetted Parts
Gun: Stainless Steel, PEEK, UHMWPE, Fluoroelastomer, Acetal, Nylon,
Polyethylene, Tungsten Wire
Waterborne Fluid Hose: PTFE
Suction Tube: Polyethylene, Stainless Steel
Merkur Pump: See manual 3A0732.
3A2497C