15
307-785
Flushing
NOTE: Use this chart to determine the required order for flushing the sprayer.
*Use this category for flushing a brand new sprayer and flushing after storage.
System has
this fluid in it:
Next fluid to be
sprayed
Flushing order:
Follow this step before
you use or store the
this fluid in it:
sprayed.
Flush 1
Flush 2
Flush 3
you use or store the
sprayer.
*Oil-based
solvent or paint
Oil-based paint –
new color
Use mineral
spirits.
none
none
Prime the sprayer with oil-
based paint.
Oil-based
solvent or paint
Water-based paint
Use mineral
spirits.
Use warm
soapy water.
Use clean
water.
Prime the sprayer with
water-based paint.
Oil-based
solvent or paint
Prepare the
sprayer for
storage
Use mineral
spirits.
none
none
Relieve the pressure.
Leave drain valve open.
Water or water-
based paint
Water-based paint
– new color
Use warm
soapy water.
Use clean
water.
none
Prime the sprayer with
water.
Water or water-
based paint
Oil-based paint
Use warm
soapy water.
Use clean
water.
Use mineral
spirits.
Prime the sprayer with oil.
Water or water-
based paint
Prepare the
sprayer for
storage
Use warm
soapy water.
Use clean
water.
Use mineral
spirits.
Relieve the pressure.
Leave drain valve open.
CAUTION
Never allow water to freeze in the pressure control.
If water freezes in the pressure control, it may be
seriously damaged and the sprayer may not start.
Always pump the water out with mineral spirits
before the water could freeze in the pressure con-
trol.
WARNING
To reduce the risk of static sparking and splashing
when flushing, always remove the spray tip from
the gun and hold a metal part of the gun firmly to
the side of a grounded metal pail.
WARNING
To reduce the risk of a serious injury, follow the
Pressure Relief Procedure on page 4 whenever
you are instructed to relieve the pressure.
1.
Relieve the pressure.
2.
Turn the pressure–adjusting knob (A) fully counter-
clockwise to the minimum pressure.
3.
Remove the spray tip from the gun. Remove the
filter bowl (B) and the screen (C), but leave the
support (D) in place. Install the bowl without the
screen. See Fig. 7.
4.
Put the suction tube into a grounded metal–pail
with 1/2 gallon (2 liters) of a compatible solvent.
5.
Start the sprayer. See page 12. To save the fluid
still in the sprayer, trigger the gun into another
container until the next fluid appears, then trigger
the gun back into the fluid you are pumping. Circu-
late the flushing fluid for a few of minutes to thor-
oughly clean the system.
6.
Do not run the pump dry for more than 30 seconds
to avoid damaging the pump packings!
7.
Relieve the pressure. Lock the gun trigger safety.
8.
Unscrew the filter bowl (B) and reinstall the clean
screen (C). Install the bowl and hand tighten it.
Fig. 7
74
A
B
C
D
Summary of Contents for Ultra 1000
Page 45: ...45 307 785 Notes ...