Start Up
16
3A3529C
3.
Remove outlet valve and clean. Make
certain outlet ball moves free in the
housing.
Install outlet valve and repeat
Flush
Storage Fluid
, page 14.
4.
Remove suction tube. Remove inlet
valve and clean. Make certain the
spring is facing up when the inlet ball
and valve are installed.
Install inlet valve and suction tube and
repeat
Flush Storage Fluid
, page 14.
ProLTS Inlet Valve Removal
An integrated tool is included in the frame to
remove the inlet valve assembly from the
pump. If you suspect that the inlet valve is
clogged or stuck, remove the valve assembly
and clean or replace. Insert pump inlet into
frame and loosen the inlet valve. Remove
inlet valve.
ti30578a
LTS15/LTS17
ti30589a
ProLTS
NOTICE
Do not lose the ball and spring inside the inlet
valve assembly. It may fall out when the inlet
valve is removed. Pump will not prime without
the ball and spring.
ti27479a