background image

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

This manual contains English. MM 311689

Graco Headquarters:

Minneapolis

International Offices:

Belgium, China, Japan, Korea

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441

Copyright 2006, Graco Inc. is registered to ISO 9001

www.graco.com

Revised 09/2009

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE

.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO

. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to

the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com.

TO PLACE AN ORDER,

contact your Graco distributor, or call this number to identify the distributor closest to you:

1-800-328-0211 Toll Free

612-623-6921

612-378-3505 Fax

Summary of Contents for TRITON 3D350HP

Page 1: ...Air Operated Double Diaphragm Pump with BSPP Fittings Part No 253708 Series D 3 1 Ratio Air Operated Double Diaphragm Pump with npt Fittings 0 6 MPa 6 bar 88 psi Maximum Air Input Pressure 1 8 MPa 18...

Page 2: ...11 Lubrication 11 Flushing and Storage 11 Tighten Threaded Connections 11 Preventive Maintenance Schedule 11 Troubleshooting 12 Repair 14 Prepare the Pump for Repair 14 General Repair Notes 14 Fault...

Page 3: ...g protection when operating this equipment Comply with all applicable local state and national fire electrical and safety regulations PRESSURIZED EQUIPMENT HAZARD Spray from the gun hose leaks or rupt...

Page 4: ...pump in an appropriate container to catch the fluid if a diaphragm ruptures MOVING PARTS HAZARD Moving parts such as the diaphragm shaft can pinch or amputate your fingers Before servicing the equipm...

Page 5: ...are adequately sized and pressure rated for your system Reference numbers and letters in parentheses refer to the reference numbers in the figures and the parts list on page 23 Tighten Threaded Connec...

Page 6: ...during operation 3 Using the wall bracket B as a template drill 5 8 in mounting holes in the wall See page 27 for a wall mounting diagram Mount the bracket 1 2 1 5 m 4 5 ft above the floor 4 Attach t...

Page 7: ...upstream from all other air line accessories 2 Install a grounded flexible air hose A between the accessories and the pump air inlet See Technical Data on page 25 to determine the air inlet size of yo...

Page 8: ...Supply G Fluid Drain Valve H Fluid Shutoff Valve J Fluid Line K Mounting Bracket L Internal Air Relief Valve M Muffler N Air Line Quick Disconnect Coupler P Pump Air Piston R Pump Diaphragms S Pump B...

Page 9: ...No 238909 Air and fluid hoses Use only electrically conductive hoses Air compressor Follow manufacturer s recommen dations Fluid supply drum Follow your local code All solvent pails used when flushin...

Page 10: ...7 With the pump air regulator C closed open the bleed type master air valve B 8 If the fluid hose has a dispensing device hold it open while continuing with the following step 9 Slowly open the air re...

Page 11: ...Check and re torque all screws and fasteners at least every two months Re torque the fluid cover screws first followed by the manifold screws NOTE Before using pump loosen fluid cover screws 31 1 2 t...

Page 12: ...cky or leaking check valves Clean or replace balls 56 and seats 53 See page 19 Ruptured diaphragm 14 Replace See page 15 Do not exceed maximum air input pressure Restricted exhaust Remove restriction...

Page 13: ...ll Check Diaphragm Air Piston Inlet Ball Check Outlet Manifold Tube Fluid Inlet Inlet Manifold Tube Outlet Ball Check Diaphragm Inlet Ball Check Diaphragm Shaft Optional Fluid Outlet Air Valve Air Val...

Page 14: ...ditional damage Tools Required 4 5 6 8 and 10 mm allen wrenches 13 mm open end wrench 28 mm open end wrench or adjustable wrench two flat blade screwdrivers 2 Phillips screwdriver internal snap ring p...

Page 15: ...e new diaphragm 14 into the shaft by hand See FIG 6 2 Depress the first diaphragm 14 using the dia phragm repair tool and install the opposite dia phragm 14 by hand 3 Remove the o rings 13 from the fl...

Page 16: ...Repair 16 FIG 6 Replace the Diaphragms 13 12 13 14 13 12 13 14 31 31 1 40 1 2 3 Lubricate Torque to 20 N m 15 ft lb 1 2 2 1 1 1 1 2 TI1959A 4 4 TI8632A TI8633A Diaphragm Repair Tool 261695...

Page 17: ...l the o rings 19 20 on the three bearings 18 Install the bearings in the center housing 5 cylinder inner cover 6 and cylinder outer cover 11 Secure with the clips 21 2 Install the carriage 45 in the c...

Page 18: ...Check that the felt strips 71 are in place on the inside of the top 67 and bottom 66 covers Install the covers The hole for the air inlet fitting must align with the port in the center housing 5 Tight...

Page 19: ...59 and seal 58 4 Install the inlet tube assembly Torque the screws 38 to 10 N m 7 4 ft lb Ball Check Valve Repair Kit 243154 is available Parts included in the kit are marked for example 56 For the b...

Page 20: ...pair 20 FIG 8 Replace the Ball Check Valves 12 38 2 65 57 56 55 54 59 53 65 57 56 53 59 58 3 38 12 4 38 58 53 56 57 65 59 65 57 56 55 54 38 4 59 53 59 59 Torque to 10 N m 7 4 ft lb 1 1 1 1 1 TI1960A 1...

Page 21: ...hous ing 5 Do not lose the o ring 28 Reassembly 1 Install the o rings 42 28 in the housing 5 2 Install the o rings 22 25 on the inner cover 6 3 Install the o ring 23 packing 26 and quad ring 32 on th...

Page 22: ...l the flat seals 55 59 and the other ball check parts see page 19 17 Install the tube assemblies Torque the screws 38 to 10 N m 7 4 ft lb FIG 9 Replace the Cylinder and Piston Seals 38 37 36 35 33 67...

Page 23: ...67 5 13 12 13 38 2 65 57 56 55 54 59 53 1 31 65 57 56 53 59 58 3 38 13 12 13 68 66 68 7 22 22 11 20 18 19 21 14 4 38 10 9 58 59 53 56 57 65 31 1 59 65 57 56 55 54 53 21 19 18 20 29 30 17 46 28 6 25 24...

Page 24: ...21 CLIP c spring 3 22 O RING nitrile 2 23 O RING nitrile 1 24 15A031 TUBE air valve 1 25 117006 O RING nitrile 1 26 PACKING PTFE 1 27 117023 PIN spring 1 28 117012 O RING fluoroelastomer 2 29 117028 S...

Page 25: ...le 11 oz cycle Operating temperature range 10 80 C 50 176 F Dry suction lift 2 5 m 8 2 ft Wet suction lift 6 7 m 22 ft Air inlet size Model 253707 1 2 BSPP f Model 253708 1 2 npt f Fluid inlet size Mo...

Page 26: ...6 0 4 0 2 7 6 15 1 22 7 30 2 37 8 45 4 52 9 60 5 68 0 75 6 83 2 Key A 0 6 MPa 6 bar 88 psi B 0 4 MPa 4 bar 60 psi C 0 2 MPa 2 bar 30 psi Fluid Flow Air Consumption A B C C B A 2 4 6 8 10 12 14 16 18 2...

Page 27: ...oles Air Inlet see page 25 for sizes Fluid Inlet see page 25 for sizes Fluid Outlet see page 25 for sizes TI1964A TI1963A 100 mm 4 in 260 mm 10 25 in TI2118 Four 9 mm 0 35 in diameter holes to mount t...

Page 28: ...p repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED...