Installation
8
309832D
Front panel display
Control
Name
Function
Loop Select Up/Down
Selects device for modification. Lights to the left of device
signify the device is ready to be modified. Enables temper-
ature Range Digit LED and Actual Temperature LED.
Set Temperature
Increment/Decrement
Selects the temperature range digit and set point tempera-
ture.
Loop Select On/Off
Turns specified device settings (auxiliary, hose, head) on
or off. Does not affect the tank zone. Lights to the right of
the device will show if device is on or off. Changes °F or
°C temperature setting.
Pump Function Toggle
Selects the pump settings Cycle, Crawl, or Run:
•
CYCLE: Pump runs when applicator is actuated.
For automatic application, the pump will run when timer is
activated.
•
CRAWL: Pump is at a constant slow turning
velocity, keeping constant pressure from the pump, to the
hose and applicator. When applicator is actuated the
pump switches to cycle setting. When applicator is off the
pump switches back to crawl setting.
•
RUN: Pump is always on.
Pump Functions
Shows GREEN when ready. Shows RED when the tank is
not ready or the Pump Control is off.
Over Temperature
Error
Flashes RED when over-temperature condition is
detected. The loop indicator LED for the affected zone
flashes RED. Heating is disabled. See
Troubleshooting
,
page 20.
Open Sensor Error
Shows RED when condition is sensed. The affected zone
is automatically de-energized. The loop indicator LED for
the affected zone flashes RED. See
Troubleshooting
,
page 20.
Actual Temperature
Displays actual temperature (°F or °C) for selected zone.