Operation
309858K
15
Daily Start-up Procedure
There are 2 ways to start up the system:
•
Manually start the system each day
•
Use the optional 7-day timer to automatically heat
up the system
Starting System Manually
1.
Verify that the main disconnect is ON.
2.
Turn the CONTROL switch (65) to ON. F
. 5, page
17.
3.
Turn the HEAT switch (66) to ON. Pump will not
operate until 30 minutes have elapsed, allowing
material to fully heat.
4.
Open the dispense valve over a waste container to
relieve pressure when material heats and expands.
5.
After each of the dispense zones is heated to oper-
ating temperature, wait an additional 30 minutes to
allow the material to heat fully.
6.
Make sure that all material valves are open.
7.
Turn the pump air supply ON and set the regulator
for normal operation.
8.
Dispense material into a waste container. Adjust the
flow rate as needed.
Using Optional 7-Day Timer
The 7-day timer can be set to automatically turn the heat
on to the system. Using the timer requires you to:
•
Create a schedule and program it into the 7-day
timer, located on the electrical control panel. Be
sure to allow at least 30 minutes for the material to
heat up before the supply unit is used. For timer pro-
gramming information, see the electronic control
panel documentation.
•
Perform a nightly procedure to ready the system for
automatic operation.
Nightly Procedure:
1.
Turn the CONTROL switch (65) to AUTO. F
page 17.
2.
Turn the HEAT switch (66) to ON.
4.
Open the dispense valve over a waste container to
relieve pressure when material heats and expands.
5.
Make sure that all material valves are open.
6.
Make sure the pump air supply has been turned off.
WARNING
•
Material and equipment are hot. Avoid contact.
Wear protective clothing.
•
Keep hands and fingers away from limit switches
and other moving parts.
•
WARNING
Read warnings, page 4.
Internal timer controls pump startup. Adjust timer if
shorter startup time is desired.
WARNING
3.
Follow Pressure Relief Procedure, page 14.
WARNING
Read warnings, page 4.
Summary of Contents for Therm-O-Flow 20
Page 43: ...Parts 309858K 43...
Page 48: ...Electrical Schematic 48 309858K Electrical Schematic Part No 617300...
Page 50: ...Electrical Schematic 50 309858K Part No 617484...
Page 52: ...Electrical Schematic 52 309858K Part No 617485...
Page 54: ...Electrical Schematic 54 309858K Part No 617349...
Page 61: ...Dimensions 309858K 61 15 1 Pump President Air Motor Ram 52 1 in 1323 mm 75 in 1905 mm...