![Graco T-MAX 506 Operation - Repair - Parts Download Page 16](http://html1.mh-extra.com/html/graco/t-max-506/t-max-506_operation-repair-parts_2251808016.webp)
Preparation
16
3A6748B
Preparation
Grounding
This product is equipped with a cord having
a grounding wire with an appropriate
grounding plug. The plug must be plugged
into an outlet that is properly installed and
grounded in accordance with all local codes
and ordinances.
Do not modify the plug provided; if it does not
fit the outlet, have the proper outlet installed
by a qualified electrician.
Solvent-Based Materials
NOTE:
All hoses sent with the unit are for
water-based material application only.
Solvent compatible hoses and applicators
must be used.
Flush the Equipment
•
Flush before changing materials, before
fluid can dry or cure in the equipment, at
the end of the day, before storing, and
before repairing equipment.
•
Flush with a fluid that is compatible with
the fluid being dispensed and the
equipment wetted parts.
•
Flush at the lowest pressure possible.
Check connectors for leaks and tighten
as necessary.
1.
Follow
2.
Set pump to lowest possible fluid
pressure, and start pump.
3.
Hold a metal part of the gun firmly to a
grounded metal pail. Trigger the gun
until clean solvent dispenses.
Amp Switch
Select 15A or 20A depending on your circuit
rating. 110V units require 100-120 VAC,
50/60 Hz, 15 – 20A, 1 phase
Select 10A or 16A depending on your circuit
rating. 230V units require 220-240 VAC,
50/60 Hz, 10 – 16A, 1 phase
The equipment must be grounded to
reduce the risk of static sparking and
electric shock. An electric or static spark
can cause fumes to ignite or explode. An
improper ground can cause electric shock.
A good ground provides an escape wire for
the electric current.
To avoid fire and explosion, always
ground equipment and waste container.
To avoid static sparking and injury from
splashing, always flush at the lowest
possible pressure.
Summary of Contents for T-MAX 506
Page 53: ...Repair 3A6748B 53 6 Install motor cover using four screws 7 Connect pump to hopper ...
Page 63: ...Repair 3A6748B 63 Cross Section Reference Pump Ball Identification 6912 ...
Page 67: ...Notes 3A6748B 67 Notes ...
Page 68: ...Parts Hopper Frame 68 3A6748B Parts Hopper Frame b a ...
Page 70: ...Parts Power Module 506 657 70 3A6748B Parts Power Module 506 657 PAGE 78 PAGES 74 75 ...
Page 72: ...Parts Power Module 6912 72 3A6748B Parts Power Module 6912 PAGE 80 PAGE 76 ...
Page 76: ...Parts Pump 25E668 6912 76 3A6748B Parts Pump 25E668 6912 ...
Page 78: ...Parts Control Box 506 657 78 3A6748B Parts Control Box 506 657 ...
Page 81: ...Wiring Diagrams 3A6748B 81 Wiring Diagrams 506 657 ...
Page 82: ...Wiring Diagrams 82 3A6748B 6912 US ...