background image

Technical Data

SoloTech

SoloTech

SoloTech Peristaltic

Peristaltic

Peristaltic Pumps

Pumps

Pumps

U.S.

U.S.

U.S.

Metric

Metric

Metric

Technical

Technical

Technical Specifications

Specifications

Specifications for

for

for the

the

the Graco

Graco

Graco Motor

Motor

Motor Control

Control

Control

(All installations and wiring must comply with NEC and local electrical codes.)

DC Power Supply

Class 2 Power Supply only

Approvals

UL508C

Conformity

CE-Low Voltage (2006/95/EC),

EMC (2004/108/EC), and RoHS

(2011/65/EU) Directives

Ambient Temperature

-40°F – 104°F

–40°C – 40°C

Environment Rating

Type 4X, IP 66

Overtemperature Sensing Specifications (The drive is provided
with a means to accept and act upon a signal from a thermal
sensor in the motor. Motor overtemperature sensing is required
to provide the motor overload protection.)

0–3.3 VDC, 1mA maximum

Weight

10.5 lb.

4.8 kg

Input

Input

Input Specifications

Specifications

Specifications

Input Line Voltage

120/240 VAC, line-to-line

Input Line Phasing

Single Phase

Input Line Frequency

50/60 Hz

Input Current per Phase

16A

Maximum Branch Circuit Protection Rating

20A, Inverse Time Circuit Breaker

Short Circuit Current Rating

5 kA

Output

Output

Output Specifications

Specifications

Specifications

Output Line Voltage

0–264 VAC

Output Line Phasing

Three Phase

Output Current (Current limit, set via the software, is provided
as a secondary protection from motor overload.)

0–12A

Output Power

1.92 KW / 2.6 hp

Output Overload

200% for 0.2 seconds

26

3A3367H

Summary of Contents for SoloTech

Page 1: ...for use use use in in in explosive explosive explosive atmospheres atmospheres atmospheres or or or hazardous hazardous hazardous locations locations locations unless unless unless otherwise otherwis...

Page 2: ...ocedure 9 Before You Start 9 Drain the Lubricant 9 Remove the Front Cover 9 Replace the Hose 10 Replace the Roller 12 Complete Pump Repair 13 Parts 18 Kits and Accessories 23 Technical Data 24 Related...

Page 3: ...eed gear reducer 26 26 26 26 mm LAC LAC LAC AC motor with low speed gear reducer 30 30 30 30 mm MPM MPM MPM Brushless DC BLDC motor with gear reducer HC HC HC High speed gear reducer no motor IEC HN H...

Page 4: ...static sparking Ground all equipment in the work area See Grounding Grounding Grounding instructions Keep work area free of debris including solvent rags and gasoline Do not plug or unplug power cord...

Page 5: ...plete information about your material request Safety Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedu...

Page 6: ...isconnect all power sources TOXIC TOXIC TOXIC FLUID FLUID FLUID OR OR OR FUMES FUMES FUMES Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallow...

Page 7: ...let or outlet pressures are too high Add pulsation dampeners Lubricant level is low Add hose lubricant to the proper level Improper lubricant is being used Use only genuine Graco glycerin hose lubrica...

Page 8: ...correct hose for your application Hose has failed due to normal wear Replace Excessive pulsations have weakened the hose If you pump is equipped with a pulsation dampener adjust its pressure If you do...

Page 9: ...ration of the pump can cause serious injury Remove the fan cover only after the motor has been locked out Drain Drain Drain the the the Lubricant Lubricant Lubricant 1 Hold a pail under the drain plug...

Page 10: ...remove the four nuts 35 from the hose barb assembly on one port Pull the hose so it extends about 2 3 in 51 76 mm out of the pump Remove the nuts 35 from the barb assembly on the other port and pull...

Page 11: ...8 ft lb 24 4 N m 7 Loop the hose 360 degrees and insert the second end through the opposite side port 8 Repeat steps 3 6 9 The roller must be moved to install the hose Follow the directions for your p...

Page 12: ...e replacing the roller continue with the next section Install Install Install the the the Roller Roller Roller 1 Lubricate the eccentric shaft 9 with hose lubricant Slide the roller 11 onto the shaft...

Page 13: ...m Remove Remove Remove the the the Motor Motor Motor Output Output Output Shaft Shaft Shaft See Figure 4 on page 15 1 Remove the four screws 31 and washers 21 that hold the gearbox and motor assembly...

Page 14: ...place all worn parts NOTICE NOTICE NOTICE The pump housing is aluminum To help prevent galling inspect the bolt threads for foreign material and clean or replace if necessary Install Install Install t...

Page 15: ...8 into the bore at the front of the pump housing 1 The lips of the seals must face toward the shaft bearings Do not install the seals past the plane of the housing NOTE NOTE NOTE If the seals are inst...

Page 16: ...el Model Model Torque Torque Torque ST10 and ST23 8 ft lb 10 8 N m ST26 18 ft lb 24 4 N m ST 30 32 ft lb 43 4 N m Install Install Install the the the Eccentric Eccentric Eccentric Shaft Shaft Shaft 1...

Page 17: ...icant if pumping strong oxidizer or acids Keep the pump properly filled with genuine Graco hose lubricant NOTICE NOTICE NOTICE The vent and drain port threads are aluminum To help prevent galling insp...

Page 18: ...Parts Parts Parts Parts 18 3A3367H...

Page 19: ...Ref Ref Part Part Part Description Description Description Qty Qty Qty 24 24Y825 CLAMP hose size 12 2 25 GASKET hose plate 2 26 17B693 PLATE hose barb 2 27 17B690 FLANGE hose barb 2 BARB hose kit inc...

Page 20: ...Ref Ref Part Part Part Description Description Description Qty Qty Qty 24 24Y826 CLAMP hose size 20 2 25 GASKET hose plate 2 26 17B694 PLATE hose barb 2 27 17B691 FLANGE hose barb 2 BARB hose kit inc...

Page 21: ...ption Description Description Qty Qty Qty 24 24Y827 CLAMP hose size 28 2 25 GASKET hose plate 2 26 17B695 PLATE hose barb 2 27 17B691 FLANGE hose barb 2 BARB hose kit includes o ring ref 44 24Y819 Sta...

Page 22: ...Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 25 GASKET hose plate 2 26 17B696 PLATE hose barb 2 27 17B692 FLANGE hose barb 2 BARB hose kit includes o ring ref 44 24Y822...

Page 23: ...art Part Part Description Description Description 17H389 9 8 ft 3 0 m 17H390 24 6 ft 7 5 m 17H391 52 5 ft 16 m Controller to Motor Controller to Motor Controller to Motor Cables Cables Cables Preassem...

Page 24: ...ximum Maximum Maximum Flow Flow Flow ST10 0 67 gpm 2 5 lpm ST23 4 5 gpm 17 0 lpm ST26 9 8 gpm 37 1 lpm ST30 15 8 gpm 59 8 lpm Fluid Fluid Fluid Capacity Capacity Capacity per per per Revolution Revolu...

Page 25: ...0 39 in 10 mm ST23 0 91 in 23 mm ST26 1 02 in 26 mm ST30 1 18 in 30 mm Weight Weight Weight ST10 55 65 lbs 25 29 kg ST23 100 120 lbs 45 54 kg ST26 190 215 lbs 86 98 kg ST30 235 285 lbs 107 129 kg Noi...

Page 26: ...ovided with a means to accept and act upon a signal from a thermal sensor in the motor Motor overtemperature sensing is required to provide the motor overload protection 0 3 3 VDC 1mA maximum Weight 1...

Page 27: ...Notes Notes Notes Notes 3A3367H 27...

Page 28: ...GRACO MAKES MAKES MAKES NO NO NO WARRANTY WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERC...