Installation
4
313291D
Installation
Grounding
The equipment must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for the electrical current due to static build
up or in the event of a short circuit.
Pump: connect the ground wire (A) firmly to a metal
part of the tank such as the swivel (B) at the base of the
regulator. Connect the other end of the wire to a true
earth ground. See F
. 1. Order Part No. 237569
Ground Wire and Clamp.
Air compressor: follow manufacturer’s
recommendations.
Object being sprayed: follow local code.
Solvent pails used when flushing: follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive sur-
face, such as paper or cardboard, which interrupts
grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of the spray gun
firmly to the side of a grounded metal pail, then trigger
the gun.
WARNING
WARNING
WARNING
WARNING
PRESSURIZED ALUMINUM PARTS HAZARD
Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids
containing such solvents in pressurized aluminum equipment. Such use can cause serious chemical
reaction and equipment rupture, and result in death, serious injury, and property damage.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating
area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic
fumes, burns, and hearing loss. This equipment includes but is not limited to:
•
Protective eyewear
•
Clothing and respirator as recommended by the fluid and solvent manufacturer
•
Gloves
•
Hearing protection
F
IG
. 1: Ground the equipment
ti12985a
B
A