Fluid Circulation
309551C
33
Circulation Through Gun
Manifold
Circulating fluid through the gun manifold allows rapid
preheating of hose.
WARNING
Read warnings, page 5. Do not circulate fluid contain-
ing a blowing agent without consulting with your mate-
rial supplier regarding fluid temperature limits.
1.
Install gun fluid manifold (P) on Part No. 246362
accessory circulation kit (W).
R
W
P
TI2767A
2.
Connect high pressure circulation lines (R) to
circulation manifold. Route circulation lines back
to respective component A or B supply drum.
Use hoses rated at the maximum working pres-
sure of this equipment.
3.
Follow
4.
Turn main power ON
.
5.
Set temperature targets, see page 26. Turn on
,
, and
heat zones by press-
ing .
6.
Press
to display actual temperatures.
7.
Circulate fluid only in jog mode (see page 34)
until temperatures reach targets.
A
B