How to Spray
3A7649A
17
Clear Tip Clogs
In the event debris clogs the Spray Tip, the
sprayer is designed with a reversible Spray
Tip that quickly and easily clears the particles
without disassembling the sprayer.
1.
To unclog Spray Tip, turn Prime
Pump/Spray Knob downward to PRIME
position.
2.
Reverse Spray Tip to UNCLOG position.
3.
Set Speed Control to 10.
4.
Point sprayer into waste bucket, turn
Prime Pump/Spray Knob forward to
SPRAY position. Pull Spray Trigger for 5
seconds to clear clog.
NOTE:
If Spray Tip is still clogged, you may
have to repeat steps 1 – 4, or replace with
new Spray Tip assembly. See
5.
Turn Prime Pump/Spray Knob downward
to PRIME position. Rotate Spray Tip
back to SPRAY position. Turn Prime
Pump/Spray Knob forward to SPRAY
position, and resume spraying.
To avoid injury, never point sprayer at your
hand or into a rag!
ti29755a