Electronic Control System
26
311163ZAH
Standard Operation
NOTE:
When raising and lowering the ram plate, make
sure there are no objects obstructing the unit.
Loading the Bin
1. Open the air shutoff valves for the air controls and
pumps.
2. On the electronic control panel, press the RAM UP
button. If the ram does not elevate, increase the ram
up air regulator pressure in the pneumatic control
panel.
3. Move the bin in front of the frame.
4. Remove the lid from the fluid bin to expose the fluid
bag. If present, open the outer plastic bag and pull it
up over the sides of the bin, exposing the aseptic
inner bag.
5. Secure the bag sides by using clamps (37) and
tubes (38). See F
6. Load the bin of material into the center of the frame.
7.
Initial Startup Only:
The frame has spring-loaded
guides to stabilize the bin. Adjust the guides equally
with the screws on all four sides of the bin. Leave
enough space between guides and bin to allow for
removal of the bin.
8. Make sure the corner seals (21) are in place.
9. Use corners (39) to help guide the plate. See F
10. Press the RAM JOG button.
NOTE:
It can take 5-15 seconds for the ram plate to
start lowering.
11. Use the ram plate handles to center the ram plate
inside the bin. Be careful not to pinch the inflatable
seal when it enters the bin.
NOTE:
The ram plate stops when it contacts the
material.
F
IG
. 15
TI16235a
38
37
21
39
When raising or lowering the ram plate, keep hands
and body away from ram plate and bin lip.
Summary of Contents for SaniForce BES Series