Troubleshooting
Troubleshooting
Troubleshooting
• Prior to performing any repairs, perform the Ram
and Pump Pressure Relief procedures.
• Check all possible problems before disassembling
the ram, pump, or platen.
Problem
Problem
Problem
Cause
Cause
Cause
Solution
Solution
Solution
Closed air valve or clogged
upstream air line.
Open, clear.
Not enough ram air pressure.
Increase.
Ram will not raise or lower.
Worn or damaged air cylinder
piston.
Replace.
Ram raises and lowers too fast or
too slow (flow control adjustment
only available in enclosed control
panels).
Ram air flow needs adjusting.
Adjust flow control valves FC2
or FC3 as required. Refer to the
control panel manual for more
information.
Air leaks around cylinder rod.
Worn rod seal.
Replace.
Ram air pressure is too high.
Decrease.
Seal not fully inflated
Increase seal air pressure, check
for seal air leak. Use the flow
valve, if present.
Fluid squeezes past platen seal or
wipers.
Worn or damaged wipers.
Replace.
Closed air valve or clogged air line.
Open, clear.
Not enough ram air pressure.
Increase.
Pump running too fast.
Reduce pump speed.
Ram valve closed or clogged.
Open, clear.
Pump will not prime properly or
pumps air.
Exposed manual control Ram
director valve is dirty, worn, or
damaged.
Clean, service.
Restricted air line or inadequate
air supply.
Increase air supply line diameter
or increase air supply volume.
Insufficient air pressure; closed or
clogged air valves, etc.
Open or clean air valves, etc.
Exhausted fluid supply.
Change drum.
Pump fails to operate.
Damaged air motor.
Service.