Integrated Air Controls
4
3A5800C
Integrated Air Controls
Follow the Pressure Relief Procedure whenever you see
this symbol.
Pressure Relief Procedure
1.
Close the air motor slider valve (BH) and the main
air slider valve (BA).
NOTE: Both are relieving air valves.
2.
Set the ram director valve (BD) to DOWN. The ram
will slowly drop.
3.
Jog the ram director valve (BD) up and down to
bleed air from ram cylinder.
4.
Open dispense valve or trigger gun to relieve pump
output pressure.
Disassembly
1.
Perform the pressure relief procedure.
2.
Disconnect all hoses and tubing from existing air
control.
3.
Remove four screws and washers from the
mounting bracket and remove the integrated air
controls.
The integrated air control includes:
WARNING
PRESSURIZED FLUID HAZARD
This equipment stays pressurized until pressure is
relieved manually. To help prevent serious injury from
moving parts, or from pressurized fluid, such as
splashing in the eyes or on skin, follow the Pressure
Relief Procedure when you stop pumping and before
you clean, check, or service the equipment.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the
work area to help prevent serious injury, including eye
injury or hearing loss.
WARNING
PRESSURIZED FLUID HAZARD
This equipment stays pressurized until pressure is
relieved manually. To help prevent serious injury from
moving parts, or from pressurized fluid, such as
splashing in the eyes or on skin, follow the Pressure
Relief Procedure when you stop pumping and before
you clean, check, or service the equipment.
F
IG
. 1
A2
BE
BH
BD
D
25M879 (shown)
BB
BF
BG
BC
BA
A1
BI