Technical
Technical
Technical Data
Data
Data
SaniForce
SaniForce
SaniForce 1040
1040
1040 Air
Air
Air---Operated
Operated
Operated Double
Double
Double Diaphragm
Diaphragm
Diaphragm Pump
Pump
Pump
US
US
US
Metric
Metric
Metric
Maximum fluid working pressure
120 psi
0.8 MPa, 8 bar
Air pressure operating range
20 to 120 psi
0.14 to 0.8 MPa, 1.4 to 8 bar
Air inlet size
1/2 in. npt(f)
Maximum suction lift (reduced if balls don’t seat well
due to damaged balls or seats, lightweight balls, or
extreme speed of cycling)
Wet 30 ft
Dry: 10 ft
Wet 9.1 m
Dry: 3.0 m
Maximum size pumpable solids
0.27 in.
6.5 mm
Fluid displacement per cycle
0.17 gallons
0.64 liters
Maximum free-flow delivery
41 gpm
155.2 lpm
Maximum pump speed
240 cpm
Weight
50.5 lb
22.9 kg
Fluid
Fluid
Fluid Inlet
Inlet
Inlet and
and
and Outlet
Outlet
Outlet Size
Size
Size
Stainless Steel
1.0 in sanitary flange or RD52 x 1/6 DIN
Noise
Noise
Noise Data
Data
Data
Sound Power (measured per ISO-9614–1)
at 100 psi fluid pressure, full flow
103 dBa
Sound Pressure
at 70 psi fluid pressure and 50 cpm
85 dBa
at 100 psi fluid pressure, full flow
90 dBa
Wetted
Wetted
Wetted Parts
Parts
Parts
Wetted parts include material(s) chosen for seat, ball, and diaphragm options, plus 316 Stainless Steel
Non
Non
Non---wetted
wetted
wetted External
External
External Parts
Parts
Parts
Non-wetted external parts include 300–series SST, Nickel plated aluminum, 17-4 PH SST, Santoprene,
LDPE, VHB acrylic
24
3A6780C
Tel: 866-777-6060
Fax: 866-777-6383
Springer Pumps, LLC
Website: www.springerpumps.com
Int'l: +001 267 404 2910