background image

Cleanup

332161A

13

6.

Turn on water. Rinse paint off suction tube, prime 
tube and inlet screen. Close valve.

7.

Connect shutoff valve and garden hose to suction 
tube. Leave prime tube in waste pail.

8.

Turn Spray-Prime/Drain valve to SPRAY.

9.

Open lever on shut-off valve.

10. Turn Pressure Control knob 1/4 turn clockwise.

NOTE:

 Step 11 is for returning paint in hose back to 

paint pail. One 50-ft (15-m) hose holds approxi-
mately 1-quart (1-liter) of paint.

11. Remove paint from hose.

a.

Pull and hold gun trigger. Point gun into paint 

pail.

b.

Turn power switch ON to begin pumping paint in 

hose back into paint pail.

c.

When water comes out of gun, continue to trig-

ger gun, aiming gun into waste pail.

12. Continue triggering gun into waste pail for 1-2 

minutes, until relatively clear water comes out of 
gun.

13. Turn Spray-Prime/Drain valve to PRIME.

ti9413a

ti10443a

ti20407a

ti10447a

1/4 turn

ti20418a

ON

OFF

ti5303a

ti20411a

ti20412a

ti20406a

Summary of Contents for RentalPRO 210

Page 1: ...applications of architectural paints and coatings Model 262906 3300 psi 22 7 MPa 227 bar Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this man ual Save these instructions ti20399a 332162 312830 English 312831 Français 312832 Español 309250 ...

Page 2: ...k of electric shock When repair or replacement of the cord or plug is required do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualified electrician or serviceman when the grounding instructions are not completely understood or when in doubt as to whether...

Page 3: ...fety Data Sheets MSDS and container labels provided with the paints and solvents Follow the paint and solvents manufacturer s safety instructions Fire extinguisher equipment shall be present and working Sprayer generates sparks When flammable liquid is used in or near the sprayer or for flushing or cleaning keep sprayer at least 20 feet 6 m away from explosive vapors SKIN INJECTION HAZARD High pre...

Page 4: ...ervicing large capacitor units PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture Failure to follow this warning can result in death serious injury or property damage Do not use 1 1 1 trichloroethane methylene chloride other halogenated hydrocarbon solvents or fluids containing such ...

Page 5: ...dentification A B C D E F H J K M N S P T R A Pressure Control B ON OFF switch C Hour Meter D Power Cord E Fluid Outlet F Prime Valve H Pump J Suction Hose K Drain Hose M Fluid Hose N Gun P Tip R Guard S Trigger Safety Lock T Serial Number ID Label ...

Page 6: ...e is not fully relieved VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure Then loosen completely 4 Turn power switch OFF if unit is being shut down or will be left unattended This equipment stays pressurized until pressure is manually relieved To help prevent serious injury from pressurized fluid such as skin injection splashing fluid and moving parts follow the P...

Page 7: ...ls placed on a grounded sur face Do not place the pail on a nonconductive surface such as paper or cardboard which interrupts grounding continuity Grounding a metal pail connect a ground wire to the pail by clamping one end to pail and other end to a true earth ground such as a water pipe To maintain grounding continuity when flushing or relieving pressure hold metal part of spray gun firmly to si...

Page 8: ...spray 7 Turn power OFF 8 Plug power supply cord into a properly grounded electrical outlet 9 Turn prime valve down 10 Place siphon tube set in grounded metal pail partially filled with flushing fluid See Grounding page 7 Do steps 1 6 of Startup page 9 to flush out storage oil shipped in sprayer Use water to flush water based paint or mineral spirits to flush oil based paint and storage oil ti20402...

Page 9: ...minute 6 Inspect for leaks Do not stop leaks with hand or a rag If leaks occur perform Pressure Relief Procedure page 6 Tighten fittings 7 Place siphon tube in paint pail 8 Trigger gun again into flushing pail until paint appears 9 Move gun to paint pail and trigger for 20 seconds Set gun safety ON 10 Screw tip assembly onto gun Tighten For gun assembly instructions see gun manual ti20417a ON OFF ...

Page 10: ...ray back and forth overlap by 50 4 Trigger gun before moving Release before stop ping For additional spraying information see gun manual 311861 Clearing Clogs 1 Release trigger put safety ON Rotate Spray Tip Take safety OFF Trigger gun to clear clog 2 Put safety ON Return Spray Tip to original position Take safety OFF and continue spraying Heavy Edges ti20413a ti20405a ti20404a ti20409a ti20419a t...

Page 11: ... to waste pail hold gun against pail trigger gun to thoroughly flush system 8 While continuing to trigger gun turn prime valve down Then release gun trigger Allow flushing fluid to circulate until fluid coming out of drain tube is clear 9 Raise siphon tube above flushing fluid 10 Close drain valve Trigger gun into flushing pail to purge fluid from hose This equipment stays pressurized until pressu...

Page 12: ...er spraying water based coatings 1 Perform Relieve Pressure Procedure page 6 2 Remove guard and spray tip For additional informa tion see gun manual 3 Remove siphon tube set from paint Wipe excess paint off outside of tubes 4 Unscrew inlet strainer from suction tube Place inlet screen in waste pail 5 Screw shutoff valve onto garden hose Turn lever and open valve ti5316a ti20417a ti4296a ti2895a ti...

Page 13: ...k to paint pail One 50 ft 15 m hose holds approxi mately 1 quart 1 liter of paint 11 Remove paint from hose a Pull and hold gun trigger Point gun into paint pail b Turn power switch ON to begin pumping paint in hose back into paint pail c When water comes out of gun continue to trig ger gun aiming gun into waste pail 12 Continue triggering gun into waste pail for 1 2 minutes until relatively clear...

Page 14: ... 17 Unscrew shutoff valve from garden hose Remove power flush adapter from suction tube Install inlet strainer 18 Close drain valve Turn power ON Trigger gun into flushing pail to purge fluid from hose 19 Turn pressure control knob all the way down and power switch OFF Unplug sprayer ti5316a ti10445a ti10448a ti20407a ON OFF ti5303a Flush ti20417a ti5316a ti4296a ...

Page 15: ...ar Cycles per gallon liter 680 180 Maximum delivery gpm lpm 0 47 1 8 Maximum tip size 0 021 Fluid outlet npsm 1 4 in Dimensions Length 26 0 in 66 0 cm Width 20 5 in 52 1 cm Height 21 0 in 53 3 cm Weight 50 lbs 22 7 kg Wetted parts zinc and nickel plated carbon steel nylon stainless steel PTFE Acetal leather UHMWPE aluminum tungsten carbide Noise level Sound power IS0 3744 100dBa Sound pressure ISO...

Page 16: ...ment claimed to be defective to an authorized Graco distributor for verification of the claimed defect If the claimed defect is verified Graco will repair or replace free of charge any defective parts The equipment will be returned to the original purchaser transportation prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reason...