background image

Warnings 

4

3A5540D

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The 
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. 
When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. 
Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this 
manual where applicable.

WARNING

ELECTRIC SHOCK HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause 
electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing 
or installing equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local codes and 
regulations.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. See 

Technical Specifications

 in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical 

Specifications

 in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For 

complete information about your material, request Safety Data Sheets (SDSs) from distributor or 
retailer.

Do not leave the work area while equipment is energized or under pressure.

Turn off all equipment and follow the 

Pressure Relief Procedure 

when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine 
manufacturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and 
create safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing 
equipment, follow the 

Pressure Relief Procedure

 and disconnect all power sources.

Summary of Contents for Reactor 25D612

Page 1: ...only Models 25D612 25E656 Important Safety Instructions Read all warnings and instructions in this manual and in the Reactor 2 manual Save all instructions IMPORTANT By operating your Reactor 2 system...

Page 2: ...15 Accessories 15 Technical Specifications 17 Graco Standard Warranty 18 Graco Information 18 Models Related Manuals Kit Included Cellular Module Description 25D612 25M720 3G cellular module operatio...

Page 3: ...Agency Approvals NOTE Cellular module kit 25M833 contains Part 25M720 Cellular module kit 25E658 contains Part 25N372 Description Approvals MODULE cellular worldwide 25M720 MODULE cellular United Sta...

Page 4: ...are compatible with equipment wetted parts See Technical Specifications in all equipment manuals Read fluid and solvent manufacturer s warnings For complete information about your material request Saf...

Page 5: ...Warnings 3A5540D 5...

Page 6: ...Typical Installation 6 3A5540D Typical Installation FIG 1 Typical Reactor Connect Cell Module Installation Reactor 2 Electric Shown WL D A C D B E F CA AA...

Page 7: ...Reactor 2 Electric Shown WL D ADM B A D F E C AA Ref Description A Cellular Module AA Cellular Module Nuts ADM Advanced Display Module B Antenna C Bracket CA Bracket Screws D Cellular Module CAN Cable...

Page 8: ...ed by an on site operator In any lock out tag out procedure take into consideration the potential for changes to the Reactor 2 settings due to remote operation To avoid injury due to unexpected machin...

Page 9: ...the unattached end of the cellular CAN cable 13 Slide the CAN cable to the top inside corner of the electrical cabinet door NOTE To minimize cable strain during door operation locate the CAN cable as...

Page 10: ...n you may see the following screens 8 Remove the software update token 9 Replace the token access panel 10 Remount the ADM using the four ADM mounting screws Tighten the screws fully 11 Close and lock...

Page 11: ...re connecting the Reactor to an app for the first time Reset Reactor Key See page 13 3 To connect the app to the Reactor scan the code a Select the Scan code button on the app See FIG 4 b Using the ap...

Page 12: ...Reactor Status H Reactor Name J Menu K Reactor Power Switch L Heat Zone Settings M Heat Zone On Off N Heat Zone Actual Temperature P Heat Zone Temperature Setpoint R Proportioner Start Stop Switch S...

Page 13: ...remotely changing or viewing Reactor settings without first reconnecting to the Reactor 1 On the Reactor ADM Cellular screen press to reset the Reactor key 2 Press to confirm resetting the Reactor key...

Page 14: ...le status LEDs are illuminated No power to cellular module Turn Reactor proportioner on Ensure cellular module is properly installed See Installation page 9 No network connection Still establishing ce...

Page 15: ...cellular module worldwide 1 25E658 KIT cellular module United States and Canada only 1 3 25M828 ANTENNA paddle 1 4 127158 NUT 8 32 2 5 121002 CABLE can 1 6 124654 TEE CAN 1 7 25M832 TAG agreement not...

Page 16: ...Parts 16 3A5540D...

Page 17: ...U201 Band Support Band 19 800 MHz Band 5 850 MHz Band 8 900 MHz Band 2 1900 MHz Band 1 2100 MHz WCDMA HSDPA HSUPA Power Class Power Class 3 24 dBm for WCDMA HSDPA HSUPA mode Cellular Module 25N372 FC...

Page 18: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...

Reviews: