background image

Operation 

4

3A6943A

Operation

The Remote Extender is configured for Dynamic Host 
Configuration Protocol (DHCP). On most networks, the 
Remote Extender automatically connects to the local 
network. It is recommended that the facility’s IT depart-
ment be contacted to provide the Remote Extender a 
reserved IP address located on the same sub-network 
as the Pulse HUB. 

Remote Extender Discovery

1.

Pulse HUB is stable on the local network at a fixed 
IP address.

2.

Connect the Ethernet to the Remote Extender 
(F

IG

. 3).

3.

Connect the power adapter to the Inlet Port. The 
other end of the power adapter is plugged into a 
120-240VAC electrical outlet.

4.

Place Pulse HUB into Discovery Mode to begin the 
process of connecting the Remote Extender to the 
Pulse HUB.

NOTE: If the Remote Extender is in the initial listening 
state, this should only take a few seconds.

5.

After the Remote Extender is found, exit Discovery 
Mode on the Pulse HUB.

Device Discovery

1.

From the Pulse software, navigate to the Device 
Network Screen. 

2.

There are multiple sections listed under the Device 
Network header, one for the HUB and others for the 
Remote Extenders.

3.

Toggle on Discovery Mode under the Remote 
Extender section.

4.

Register devices with the Remote Extender 
following the instructions for your devices, similar to 
the device registration process for the HUB.

F

IG

. 3: Connecting Ethernet

Summary of Contents for Pulse 25P363

Page 1: ... creates a supplementary Pulse Device Network It connects to the Pulse HUB over the facilities LAN Not approved for use in European explosive atmosphere locations For Indoor use only Part 25P363 Important Safety Instructions Read all warnings and instructions in this manual before using the equipment Save these instructions ...

Page 2: ... Pulse Remote Extender The Pulse Remote Extender sends component information to the Pulse HUB using a user supplied Local Area Network LAN connection FIG 1 1 Button Not used 2 LED Status Lights Power indicates power is on when lit Xbee indicates hardware configuration is active when lit Network indicates network is active when lit 3 Power Inlet Port 5VDC 4 Ethernet Network Connection FIG 1 Pulse R...

Page 3: ...r high on a wall or on the ceiling Install the Pulse Remote Extender on an unobstructed line of sight of any Meters Pump Air Controls or Tank Level Monitors FIG 2 Installation should comply with all applicable local state and national fire electrical and safety codes and regulations FIG 2 Example of Facility Layout ...

Page 4: ...wer adapter is plugged into a 120 240VAC electrical outlet 4 Place Pulse HUB into Discovery Mode to begin the process of connecting the Remote Extender to the Pulse HUB NOTE If the Remote Extender is in the initial listening state this should only take a few seconds 5 After the Remote Extender is found exit Discovery Mode on the Pulse HUB Device Discovery 1 From the Pulse software navigate to the ...

Page 5: ...problem persists after 60 sec replace the hardware Network LED is not lit Hardware Configuration Failure Disconnect power and reconnect If problem persists after 60 sec replace the hardware Network LED flashing yellow slower than once per second No Ethernet connection Disconnect Ethernet cable and reconnect If that does not solve the issue replace the Ethernet cable Network LED is flashing yellow ...

Page 6: ... x 3 0 x 3 0 in 7 62 x 7 62 x 7 62 cm Weight 0 15 lb 0 07 kg Operating Voltage 5VDC Power Consumption Typical 1 2 W Max 2 5 W Operating Temperature 32 F to 104 F 0 C to 40 C Relative Humidity 5 to 95 non condensing RF Frequency Band 2 4 GHz ISM Maximum Transmit Power 6 3 mW 8dBm RF Range 200 ft 60 m ...

Page 7: ...s of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to inci...

Page 8: ...ces Belgium China Japan Korea GRACO INC AND SUBSIDIARIES P O BOX 1441 MINNEAPOLIS MN 55440 1441 USA Copyright 2019 Graco Inc All Graco manufacturing locations are registered to ISO 9001 www graco com Revision A June 2019 Graco Information For the latest information about Graco products visit www graco com For patent information see www graco com patents TO PLACE AN ORDER contact your Graco distrib...