Installation
3A5573C
3
Assemble the Oil Bar
The oil bar requires assembly prior to use.
1.
Attach dispenser wrapper (21) to drain
pan (22) using screws (27), lock
washers(28) and nuts (29) and existing
holes. Tighten nuts securely. (See F
2.
Use the existing mounting holes in the
back of the oil bar to secure it to a wall.
Select a location that is easily accessible
to the user and will adequately support
the weight of the oil bar, metered
dispense valves and plumbing.
NOTE:
Fasteners for this installation are
not included in the kit and must be
provided by the user. When selecting
fasteners consider the weight of the oil
bar, metered dispense valves, plumbing
fixtures and dispensed oil in the
container placed on the shelf. See
Technical Specifications, page 10.
3.
Attach the meter mounting plate (24) to
the wrapper dispenser (21) using screws
(27), lock washers(28) and nuts (29) and
existing holes. Tighten nuts securely.
Refer to F
. 6 for the correct installation
orientation for these parts.
4.
Connect cover panel plate (25) to meter
mounting plate (24) using screws (27)
and existing holes. Tighten screws
securely. Refer to F
. 7 for the correct
installation orientation for these parts.
NOTE:
Do not assemble cover panel
plate (25) prior to meter installation.
5.
Install pan strainer (23) in drain pan (22).
F
IG
. 5
27
22
28
29
21
F
IG
. 6
F
IG
. 7
24
21
28, 29
27
25
27
24
Summary of Contents for Pulse 25D121