Installation
2
310676A
Installation
1.
Flush system (see proportioner operation manual).
2.
Relieve pressure (see proportioner operation man-
ual).
3.
Remove screws (B, C) and take the integrator
assembly (A) off the proportioner mix manifold (M).
See
, page 5. Keep the integrator assembly for
reuse.
4.
Install the remote manifold body (1) from the kit onto
the proportioner where the integrator assembly was
removed, using the screws (B, C). See F
5.
Assemble the remaining parts of the remote mani-
fold kit to the integrator assembly (A) removed in
step 3, as shown on page 5.
6.
Mount the integrator assembly/remote manifold as
desired, using the 1/4-20 mounting holes in the rear
of the integrator assembly block.
7.
Connect fluid lines (H) between the remote manifold
body (1, F
. 1) and the remote manifold assembly,
see
, page 5. Select appropriate fittings and
fluid line sizes and lengths.
WARNING
Use only high pressure fluid hoses rated to withstand
the maximum working pressure of the proportioner.
See proportioner operation manual.
Balance pressure drops in the two fluid lines as
instructed on page 3 to ensure an accurate mix
ratio.
WARNING
The remote manifold must be grounded. Use electri-
cally conductive hoses to remote manifold or ground
through mountings.
F
IG
. 1. Remote Manifold Body Installed on Proportioner
H (Component B Out)
H (Component A Out)
1
TI5109a