Meter Performance Data (G3000 on A, Coriolis on B)
312776K
99
Meter Performance Data (G3000 on A, Coriolis on B)
0
500
1000
1500
2000
2500
3000
3500
3800
1:1
2:1
3:1
4:1
5:1
6:1
7:1
8:1
9:1
10:1
11:1
12:1
13:1
14:1
15:1
16:1
17:1
18:1
19:1
20:1
21:1
22:1
23:1
24:1
25:1
26:1
27:1
28:1
29:1
30:1
Ratio
Flow Rate (cc/min)
50cc Dose
25cc Dose
10cc Dose
NOTE: Maximum system
flo
w
is 3800 cc/min.
Tes
t Condit
ion
s
Fluid:
Hy
draulic Oil
Viscosity:
65.7 cen
tip
oise
Ra
tio Tole
ranc
e
:
5%
Valve Setting:
1.25
T
u
rn
s
Open
(sta
nd
ard
se
tting
)
A a
nd B Fe
ed Pres
sur
e:
3
00
psig
50cc
Dose
25cc Dose