Installation
10
309293J
Fig. 2. Typical Installation: PRO Xs Waterborne System
Key
A
B*
D E
F
H
J
K*
L
M
N
P*
Q*
R
S
T
U
V*
C
G
TI1896C
Gun ES ON/OFF valve: I is ON, 0 is OFF
B*
BB
AA
Y
Z
X
W
TI1775C
A
Main Air Supply Line
B*
Main Air Supply Shutoff Valve (bleed-type)
C
Pump Air Pressure Gauge
D
Pump Air Pressure Regulator
E
kV Meter
F
Pump
G
Pump Suction Hose
H
Paint Container
J
Bleed Resistor
K*
Enclosure Safety Interlock
L
Isolated Enclosure
M
Gun Air Line Filter
N
Gun Air Pressure Regulator
P*
Graco Red Grounded Air Supply Hose
Q*
Air Hose Ground Wire
R
Graco Waterborne Fluid Hose
S
Waterborne Electrostatic Air Spray Gun
T
Grounding Rod
U
Ground Terminal
V*
Main Ground Wire
W
Strain Relief/Ground Fitting
X
Pump Air Supply Line
Y
Grounding Cylinder
Z
Pump Fluid Outlet Fitting
AA
Isolated Enclosure Door
BB
Enclosure T-Handle Locking Screw
*
Required for safe operation. Must be purchased separately.